HP XP RAID Manager Software User Manual
Page 210
Table 50 SSB codes that are returned by raidcom disconnect external_grp command (continued)
raidcom disconnect external_grp
Description
Error code
Executing/
Asynchronous
Error message
SSB2
SSB1
Call HP Technical Support.
An internal error occurred by the operation of external volume.
0905
2EDA
Executing
CMDRJE
Call HP Technical Support.
Table 51 SSB codes that are returned by raidcom modify external_grp command
raidcom modify external_grp
Description
Error code
Executing/
Async
Error message
SSB2
SSB1
The external volume group is not in the effective range.
4100
2E00
Executing
CMDRJE
The specified value of the load balance mode is invalid.
410F
2E00
Executing
CMDRJE
MP Blade ID is not in the effective range.
8301
2E00
Executing
CMDRJE
The specified MP Blade is blocked.
8300
2E10
Executing
CMDRJE
The attribute cannot be changed because Auto LUN is being
executed.
4107
2E11
Executing
CMDRJE
The load balance mode cannot be changed because the
alternative path mode is set to Single.
4303
2E11
Executing
CMDRJE
The load balance mode cannot be changed because microcodes
of multiple versions are in the storage system.
800F
2E11
Executing
CMDRJE
There is no external volume group.
4100
2E20
Executing
CMDRJE
The specified MP Blade is not installed.
8300
2E20
Executing
CMDRJE
Cache mode cannot be changed because there is an LDEV that
Cache Residency bind mode is set.
000C
2E31
Executing
CMDRJE
Cache mode cannot be changed because the specified external
volume includes a pool volume or an LDEV that is used by LUSE.
4101
2E31
Executing
CMDRJE
The cache mode cannot be changed because one of the
following applies to the specified external volume.
4107
2E31
Executing
CMDRJE
•
A pool volume of the pool that consists of both external
volumes and internal volumes.
•
A pool volume of the pool where the multi tier pool option
is enabled.
The attribute of the external volume cannot be changed from
the current cache mode to the specified cache mode.
4108
2E31
Executing
CMDRJE
The attribute cannot be changed because the external volume
group is not mapped for online data migration.
4109
2E31
Executing
CMDRJE
The specified command cannot be accepted because the
command is not supported.
00F1
2EDA
Executing
CMDRJE
An internal error occurred on the changing of an external volume
option.
0905
2EDA
Executing
CMDRJE
Call HP Technical Support.
210