Hard drive led combinations – HP StorageWorks 6000 Virtual Library System User Manual
Page 243
![background image](/manuals/397918/243/background.png)
Status
9 Fault LED (am-
ber)
8 Power LED
(green)
No power to this specific power supply
-Or-
Power supply failure
On
Off
AC power present
System in standby mode
Off
Blinking
Power supply on and working properly
Off
On
Power supply current limit exceeded
Blinking
On
Table 13 Hard drive LED combinations
Status
Fault LED
Online LED
Activity LED
Do not remove the drive. Removing a drive during this pro-
cess causes data loss.
The drive is being accessed and is not configured as part
of an array.
Off
Off
On
Do not remove the drive. Removing a drive during this pro-
cess causes data loss.
The drive is rebuilding or undergoing capacity expansion.
Off
Flashing
On
Do not remove the drive. Removing a drive during this pro-
cess causes data loss.
The drive is part of an array being selected by the Array
Configuration Utility.
-Or-
The Options ROMPaq is upgrading the drive.
Flashing
Flashing
Flashing
OK to replace the drive online if a predictive failure alert is
received, and the drive is attached to an RAID controller.
The drive is not configured as part of an array.
-Or-
If this drive is part of an array, then a powered-on controller
is not accessing the drive
.-Or-
The drive is configured as an online spare.
Off
Off
Off
OK to replace the drive online.
The drive has failed and has been placed off-line.
On
Off
Off
OK to replace the drive online if a predictive failure alert is
received (refer to the following section for details), provided
that the array is configured for fault tolerance and all other
drives in the array are online.
The drive is online and configured as part of an array.
Off
On
Off
HP StorageWorks 6000–series Virtual Library System User Guide
243