beautypg.com

Fan module locations – HP StorageWorks 6000 Virtual Library System User Manual

Page 220

background image

Status

Internal Health
LED Color

System board LED
and color

DIMM in slot X has reached single-bit correctable error
threshold.

DIMM in slot X is in a pre-failure condition.

DIMM in slot X is an unsupported type, but valid memory exists
in another bank.

Amber

No valid or usable memory is installed in the system.

Red

DIMM failure, all
slots in one bank
(Amber)

The Health Driver has detected a cautionary temperature level.

Amber

Overtemperature
(Amber)

The node has detected a hardware critical temperature level.

Red

The PCI riser board assembly is not seated.

Red

Riser interlock (Am-
ber)

Bank X failed over to the online spare memory bank.

Amber

Online spare
memory (Amber)

The power converter module is not seated.

Red

Power converter
module interlock
(Amber)

A redundant fan has failed.

Amber

Fan module (Amber)

The minimum fan requirements are not being met in one or more
of the fan modules. One or more fans have failed or are missing.

Red

Fan module (Red)

The power supply signal cable is not connected to the system
board.

Red

Power supply signal
interlock (Amber)

Fan Module Locations

Description

Item

Power supply zone fan module (fan 1)

1

Processor zone fan module (fan 2)

2

Component Identification

220