Editing the snmp settings, Edit snmp settings window – HP StorageWorks 6000 Virtual Library System User Manual
Page 180

Editing the SNMP Settings
NOTE:
To display VLS notification alerts on a management console, the management console must be running
HP Systems Insight Manager, and be configured to receive SNMP traps from the VLS.
To add a management consoles to the SNMP alert distribution list from Command View VLS:
1.
Click the Notifications tab.
The Notifications window displays.
2.
Click Edit SNMP Setting in the task bar.
The Edit SNMP Settings window opens (
).
Figure 68 Edit SNMP Settings window
.
3.
To add management consoles:
a.
Enter the host name of a management console that you want to receive VLS SNMP traps in
the Hostname box.
b.
Enter the string name that is passed with the set to get commands from the management
console in the Community String box.
This value is typically set to Public.
c.
Select the appropriate trap version for the management application that will receive the
SNMP traps in the Trap Version box.
Select 1 for the trap version if your management application is HP Systems Insight Manager.
d.
Click Add.
e.
To add another management console, repeat these steps.
You can add up to 8 management consoles.
4.
To delete a management console from the list, click the Remove button for the management
console.
Monitoring
180