Clearing the hardware compression faults – HP StorageWorks 6000 Virtual Library System User Manual

Page 196

background image

Test type — Background or Read-only

Storage pools — All or the number of the storage pool tested

Test start time

Test end time

Current job count

Total job count

Total amount of data written during the test

Total amount of data read during the test

Total number of successful jobs

Total number of failed jobs

Status of the test

Decompression errors will be logged once per occurrence. The data fields are in order as follows.
See

Log Monitor Summary

” on page 195 for descriptions not defined here:

Decompression_error — indicates that this row of data is the decompression information.

Decompression error ID

Time the error occurred

sDev Number

LBA

Offset

Length

UUID

Jobs are only logged in event of a job failure. The data fields are in order as follows:

Job — indicates that this row of data is the job information

Job ID

Date of the test

Generated job key

Test start time

Time of last update to the job

Test end time

Number of the storage pool tested

Total amount of data written during the test at this point

Direction — read or write

Result — success or fail

Message, if any, associated with the failed job

External connect error, if any

Source barcode of the job

Target barcode of the job

Clearing the Hardware Compression Faults

If the VLS node is showing a hardware compression status that you think is incorrect, or if you want
to verify the status shown, you can force a rescan of the node.

From Command View VLS:

1.

On the System tab, expand Chassis in the navigation tree.

Monitoring

196