beautypg.com

Rear panel components – HP StorageWorks 6000 Virtual Library System User Manual

Page 233

background image

Status

Description

Item

Green = Protection enabled
Flashing amber = Memory configuration error
Amber = Memory failure occurred
Off = No protection

Online spare memory LED

1

Green = Protection enabled
Flashing amber = Memory configuration error
Amber = Memory failure occurred
Off = No protection

Mirrored memory LED

2

Amber = Failure
Off = Normal. For additional information
detailing the causes for the activation of these
LEDs, refer to

HP Systems Insight Display LEDs

and Internal Health LED Combinations

.

All other LEDs

IMPORTANT:

If more than one FBDIMM slot LED is illuminated, further troubleshooting is required. Test each bank
of FBDIMMs by removing all other FBDIMMs. Isolate the failed FBDIMM by replacing each FBDIMM
in a bank with a known working FBDIMM.

NOTE:

The HP Systems Insight Display LEDs represent the system board layout.

Rear Panel Components

Description

Item

Expansion slot 1 blank

1

Expansion slot 2 blank

2

Quad port FC card, host port, port 0

3

Quad port FC card, host port, port 1

4

HP StorageWorks 6000–series Virtual Library System User Guide

233