Viewing summary of an individual acp/dka – HP XP Performance Advisor Software User Manual
Page 192
In addition, the combined backend transfer value is displayed for each ACP or DKA (applicable
for XP24000, P9500/XP7 disk arrays). For more information, see the description provided for
ACP Pair Backend group box in
“Viewing performance summary” (page 177)
Viewing summary of an individual ACP/DKA
Click an individual ACP/DKA in either the DKA summary table or the ACP/DKA summary table
to view its data. You can also do the following:
•
Select an individual ACP/DKA under the ACP component node for an XP disk array.
•
Select an individual DKA under the CHA/DKA component node for an P9500/XP7 disk array.
The following table describes the data for an individual ACP/DKA. The Yes and No given under
For XP disk arrays and For P9500/XP7 disk arrays columns indicate whether that particular data
or metric is displayed for the XP/P9500/XP7 disk array.
For P9500/XP7 disk arrays
For XP disk arrays
Individual ACP/DKA data
Summary
No
Yes
The MPs on the individual ACP/DKA and
their utilization percentage
For example, if you selected the AUMU
DKA pair, you can view the MPs and also
their utilization percentage on AU.
Similarly, you can also view the
above-mentioned details for MU.
Yes
Yes
The backend transfers for the selected
ACP/DKA pair, which includes the
sequential and non-sequential reads and
writes.
In addition, the combined backend
transfer value is also displayed as an
aggregate value for the ACP or DKA. For
more information, see the description
provided for ACP Pair Backend group box
in
RAID Group Information
Yes
Yes
•
The RAID group ID and the RAID level
•
Associated disk drives
•
Related metrics, such as the sequential
and non-sequential reads, and writes
Example:
The following image displays the ALML backend transfers and RAID group information for 53036,
which belongs to the P9500 Disk Array type.
192 Viewing XP and XP7 disk array components