2.

You can filter alarm records based on:

Array:

The Array list displays only those XP and XP7 disk arrays for which alarms are

configured.

Select the XP or XP7 disk array to view the corresponding alarm records in

the

Alarms table. Alternatively, you can also select the XP or XP7 disk array in the

component

selection tree to view the same set of alarm records in the Alarms table.

Metric

Category: The Metric Category list displays only those categories that are associated

with

the selected components. Select the metric category to view the corresponding

alarm

records in the Alarms table. Alternatively, if you select an XP or XP7 disk array in

the

component selection tree, and then choose the All or a specific metric category in

the

Metric Category list, all the alarm records configured for all or the specific metric

category

are displayed.

Metrics:

The Metrics list displays only those metrics that are associated with the selected

components.

Select the metric to view the corresponding alarm records in the Alarms

table.

Alternatively, if you select an XP or XP7 disk array in the component selection

tree,

and then choose the All or a specific metric in the Metrics list, all the alarm records

configured

for all or the specific metric are displayed.

Enabled or Disabled check box: The records in the Alarms table are filtered to show those
records for which alarm generation is enabled or disabled. If you want to view both,
select the Enabled and Disabled check boxes.

For example, if you have filtered records in the Alarms table for RAID groups, 1–3 and 1–5. Their
associated metrics are RAID Group Total IO –Frontend, RAID Group Total MB –Frontend, and RAID
Group Sequential Read Tracks –Backend. The Metrics list displays RAID Group Total IO –Frontend,
RAID Group Total MB – Frontend, and RAID Group Sequential Read Tracks – Backend metrics.
The following are the combination of records that are displayed in the Alarms table:

RAID Group 1–3 and RAID Group Total IO – Frontend metric

RAID Group 1–3 and RAID Group Total MB – Frontend metric

RAID Group 1–3 and RAID Group Sequential Read Tracks – Backend metric

RAID Group 1–5 and RAID Group Total IO – Frontend metric

RAID Group 1–5 and RAID Group Total MB – Frontend metric

RAID Group 1–5 and RAID Group Sequential Read Tracks – Backend metric

If you want to configure alarm settings only on RAID group, 1–3 for the metric, RAID Group Total
IO –Frontend, select the metric as RAID Group Total IO — Frontend from the Metrics list and Passive
from the Alarms Status list. The set of RAID group records are further filtered to display only RAID
group, 1–3 for the RAID Group Total IO – Frontend metric and Passive alarm status.

Click

Clear Filter any time while selecting values from the filter options. It removes the current

selection

and displays all the records in the Alarms table. Also, the current selection on the XP

or

XP7 disk array or component in the component selection tree is removed.

Setting threshold level

Threshold level is a value that you set and further used by HP XP7 Performance Advisor to compare
the current performance value of a selected component with the set threshold value. HP XP7
Performance Advisor triggers an alarm and sends appropriate notifications to the recipients when
the current performance value of a component goes beyond the threshold level that you configured.

NOTE:

You can also use the Ctrl + c and Ctrl + v combination to copy and paste the threshold

level from one record to another record. Ensure that the records are selected, so that the latest
changes are updated.

To set the threshold level:

Configuring notification and monitoring settings