Ethernet networks (advanced settings), Server vlan tagging support, Ethernet networks (advanced – HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 97: Settings)
Virtual Connect networks 97
Task
Action
Filter the list by a specific profile Select All Profiles or a single profile from the Filter by Profile profiles list.
The assigned networks are listed by each subport. If multiple networks are
assigned, mouse over the label to see a listing of all networks associated
with the subport.
Filter by Physical Server
Filter the list by server bay
Select All Bays or a single bay from the Filter by Physical Server bay list.
The list displays the actual server type installed in the bay, for example,
"Server Bay 1 HP ProLiant BL420c Gen8." If more than one enclosure is
imported into the domain, options are grouped according to the enclosure
name.
Filter the list by server port
Select All Ports or a single port from the Filter by Physical Server port list.
Accept selected ports and return
to the Port Monitoring screen
Click OK.
Clear newly selected ports
without saving and return to the
Port Monitoring screen
Click Cancel.
Reset the filter criteria to include
all items in each filter
Click Reset Filters.
Only display selected ports
Select the Only display selected ports check box.
Ethernet Networks (Advanced Settings)
Use this screen to perform the following tasks:
•
Set Server VLAN Tagging Support (on page
•
•
Use the Multiple Networks Link Speed Settings (on page
) to set a custom value for preferred link
connection speed or maximum link connection speed.
•
Enable or disable MAC Cache Failover (on page
•
Modify the refresh interval for MAC Cache Failover (on page
•
Enable or disable Network Loop Protection (on page
) for all VC-Enet modules in the domain.
•
Reset Network Loop Protection for all server ports in a loop-detected error state.
•
Enable or disable Pause Flood Protection (on page
) for all VC-Enet modules in the domain.
•
Reset Pause Flood Protection for all server ports in a pause flood protected error state.
•
Enable and configure Throughput Statistics ("
Configuring Throughput Statistics
" on page
) for all
ports of each VC-Enet module, including Flex-10 subports.
•
Configure domain wide LACP timer ("
" on page
Server VLAN tagging support
VLAN tunneling support
You can tunnel VLAN tags and map VLAN tags in the same domain. As of VC 3.30, tunneling and mapping
is configured at the network level, not at the domain level. Server VLAN tunneling is supported only on
networks with dedicated uplinks and cannot be used with shared uplink sets.
- Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric-20.40 F8 Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem