beautypg.com

Ethernet networks (advanced settings), Server vlan tagging support, Ethernet networks (advanced – HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 97: Settings)

background image

Virtual Connect networks 97

Task

Action

Filter the list by a specific profile Select All Profiles or a single profile from the Filter by Profile profiles list.

The assigned networks are listed by each subport. If multiple networks are
assigned, mouse over the label to see a listing of all networks associated

with the subport.

Filter by Physical Server

Filter the list by server bay

Select All Bays or a single bay from the Filter by Physical Server bay list.
The list displays the actual server type installed in the bay, for example,

"Server Bay 1 HP ProLiant BL420c Gen8." If more than one enclosure is

imported into the domain, options are grouped according to the enclosure

name.

Filter the list by server port

Select All Ports or a single port from the Filter by Physical Server port list.

Accept selected ports and return

to the Port Monitoring screen

Click OK.

Clear newly selected ports
without saving and return to the

Port Monitoring screen

Click Cancel.

Reset the filter criteria to include
all items in each filter

Click Reset Filters.

Only display selected ports

Select the Only display selected ports check box.

Ethernet Networks (Advanced Settings)

Use this screen to perform the following tasks:

Set Server VLAN Tagging Support (on page

97

).

Set VLAN Capacity (on page

98

).

Use the Multiple Networks Link Speed Settings (on page

98

) to set a custom value for preferred link

connection speed or maximum link connection speed.

Enable or disable MAC Cache Failover (on page

99

).

Modify the refresh interval for MAC Cache Failover (on page

99

).

Enable or disable Network Loop Protection (on page

100

) for all VC-Enet modules in the domain.

Reset Network Loop Protection for all server ports in a loop-detected error state.

Enable or disable Pause Flood Protection (on page

101

) for all VC-Enet modules in the domain.

Reset Pause Flood Protection for all server ports in a pause flood protected error state.

Enable and configure Throughput Statistics ("

Configuring Throughput Statistics

" on page

101

) for all

ports of each VC-Enet module, including Flex-10 subports.

Configure domain wide LACP timer ("

LACP timer configuration

" on page

102

).

Server VLAN tagging support

VLAN tunneling support
You can tunnel VLAN tags and map VLAN tags in the same domain. As of VC 3.30, tunneling and mapping

is configured at the network level, not at the domain level. Server VLAN tunneling is supported only on
networks with dedicated uplinks and cannot be used with shared uplink sets.