HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 266
Virtual Connect modules 266
Row
Description
Overall Status
Represents the worst condition of Hardware Status, VC Status, and OA
Communication Status
Hardware Status
Component health status from the Onboard Administrator
VC Status
Component health status from the Virtual Connect Manager
Assigned Server Profile
Name of the profile currently assigned to the server blade in this bay
Enclosure Name
Name of the enclosure where this server blade is installed
UID
Icon indicates whether the UID is on or off.
Power Status/Control
Icon indicates whether the server blade in that bay is powered on or off.
The following table describes the rows within the Server Blade Information table in the Server Bay Status
screen.
Server Blade Information
Row
Description
Serial Number
The unique serial number of the server blade
Serial Number (Logical)
If configured, the logical serial number of the server blade
UUID
Unique identifying number of the server blade
UUID (Logical)
If configured, the logical UUID of the server blade
Product Name
The common descriptive name of the server blade
Server Name
If configured, the server name of the installed server blade
Part Number
The part number to be used when ordering an additional or replacement server
blade of this type
Asset Tag
If configured, the asset tag of the installed server blade
Monarch Bay (multi-blade
servers only)
Identifies the monarch bay in the multi-blade server
All Bays (multi-blade servers
only)
Identifies all of the bays in the multi-blade server
The following table describes the columns within the Server Ethernet Adapter Information table in the Server
Bay Status screen.
Server Ethernet Adapter Information
Column
Description
Ethernet adapter
Port number where the adapter is installed
Flex NIC
Flexible network interface port
Location
Connection location of this adapter
Module Port
Module bay number and module port number to which the device is connected
Model
Type of adapter installed
MAC Address
MAC address of the port, either assigned by Virtual Connect or as provided by
the Ethernet adapter
Network
Network name associated with this adapter
The following table describes the columns within the SAN Ports table in the Server Bay Status screen.
SAN Ports
- Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric-20.40 F8 Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem