HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 208
Virtual Connect server profiles 208
Column name
Description
the connection.
For the HP Virtual Connect 4Gb FC Module, supported speed values include
"Auto","1Gb","2Gb", "4Gb", and "Disabled". If the value is set to 8Gb, the
speed is auto-negotiated by Virtual Connect.*
WWPN
As of VC 3.70, the actual hardware WWN for mapped connections
appears. For unmapped connections, FACTORY-DEFAULT continues to
appear. If the profile is assigned, the WWN assigned to the port appears. If
the profile is unassigned and the domain is set to show factory default
WWNs, FACTORY-DEFAULT appears. If the profile is using VC-defined
WWNs, the VC-defined WWN appears. If the profile is using hardware
WWNs, FACTORY-DEFAULT appears.
Mapping
Server hardware mapping assignment
Action
Delete a connection. Connections can be removed starting with the last
connection in the list.
FCoE HBA Connections
Port
Relative order of the FCoE port on the server receiving the profile
Connected to
Bay number of the VC module to which the port is connected
FC SAN/FCoE Network Name Name of the SAN fabric or FCoE network to which the port is connected, or
Unassigned
Type
Type of connection, SAN or FCoE depending on the fabric or FCoE selection
Status
Status of the VC module
Port Speed Type
Requested speed for the FlexFabric connection.
If an FCoE network is assigned to the connection, the supported port speed
types are "Auto", "Preferred", "Custom" and "Disabled".
If a SAN Fabric is assigned to the connection, the supported port speed types
are "1", "2", "4", "8", "Preferred", "Custom" and "Disabled".
For all port speed types, if configured, the maximum allocated port speed is
determined by the maximum connection speed for that SAN Fabric or FCoE
network.
Auto—VCM determines the appropriate port speed based on the available
bandwidth for the port.
Preferred—Use the preferred speed of the SAN Fabric or FCoE network
selected for this connection. If no preferred speed is configured, VCM
determines the speed.
Custom—Allows you to select a custom port speed setting between 100Mb
and the configured maximum connection speed in 100Mb increments.
Disabled—The FCoE connection is disabled and no bandwidth is allocated.
1,2,4, and 8Gb—Predefined custom port speed selection that can be used for
the FCoE connection assigned to a SAN Fabric.
Allocated Port Speed (Min-Max) Allocated bandwidth of the port. See "Bandwidth assignment (on page
)."
WWPN
As of VC 3.70, the actual hardware WWN for mapped connections
appears. For unmapped connections, FACTORY-DEFAULT continues to
appear. If the profile is assigned, the WWN assigned to the port appears. If
the profile is unassigned and the domain is set to show factory default
WWNs, FACTORY-DEFAULT appears. If the profile is using VC-defined
WWNs, the VC-defined WWN appears. If the profile is using hardware
WWNs, FACTORY-DEFAULT appears.
MAC
As of VC 3.70, the actual hardware MAC for mapped connections appears.
For unmapped connections, FACTORY-DEFAULT continues to appear. If the
profile is assigned, the MAC address assigned to the port appears. If the
- Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric-20.40 F8 Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem