HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 29

background image

Virtual Connect domains 29

2.

Select the Ignore enclosure serial number in restored configuration file checkbox to restore a

configuration that was generated on another enclosure. If this item is not selected, a configuration
generated on another enclosure is rejected. This option is relevant to the primary/local enclosure only.

CAUTION:

Restoring a Virtual Connect domain configuration from a backup file that was

created on another Virtual Connect domain is not supported and can cause serious faults within

this and other Virtual Connect Domains within the environment. The restore selection and

configuration files should only be used to restore the same previously existing domain.

3.

Select the Ignore firmware version in restored configuration file checkbox to allow restoring a domain
configuration from a backup file that was created using a different version of VC firmware.

IMPORTANT:

Restoring a configuration from a backup file saved by firmware version later than

what is currently running is not supported. For example, if you are currently running Virtual
Connect v3.60, you can restore a configuration from a backup file that was created using v3.10

or v3.51, but not v3.70.

4.

Enter the appropriate key if the configuration file is encrypted.

5.

Click Restore Configuration.

6.

Confirm the domain configuration to be restored, and then click OK.

If restoring a configuration file that has multiple enclosures, each remote enclosure must be re-authenticated

for security reasons.
For more information, see "Recovering remote enclosures (on page

280

)."

Domain Settings (Storage Management Credentials) screen

Use this screen to manage the credentials of HP P4000 series devices in the domain. The IP address is the IP

address of the LHN CMC interface. This IP address must be accessible from the same management network

where Virtual Connect and Onboard Administrator reside.

The following table describes the columns within the Domain Settings (Storage Management Credentials)

screen.

Column

Description

Name

Name for the iSCSI storage management

IP address

iSCSI storage management IPv4 address

Username

An administrator for the storage management

Action

Perform edit and delete operations