HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 137
Virtual Connect networks 137
Field name
Description
switch. Traffic is active on this link.
•
Linked-Standby—There is a physical connection to a VC module and a
switch. Currently there is no active traffic on this link.
•
Unlinked—There is no physical VC module or switch connection.
•
FCoE Active—An FCoE network has been defined, uplinks are
connected, and an FCoE-capable switch has been correctly configured.
•
No FCoE—An FCoE network has been defined, uplinks are connected,
but an FCoE-capable switch has not been configured, or the connection
is to a non-FCoE switch.
If the port is unlinked and no connectivity exists, the cause is displayed. For
more information about possible causes, see "Port status conditions (on
)."
ConnectorType
The type of connector on the port; for example, RJ-45
Connected To
If the individual port is connected to a switch that supports LLDP, the switch
LLDP system name or management IP address and switch port number
appear. A link is provided to obtain more information about the far-end
switch port.
PID
PID status icon (on or off) for the port
Speed/Duplex
Pull-down menu to specify the speed and duplex (where applicable) of the
uplink port. Half-duplex operations are not supported by the VC-Enet
module. For shared uplink sets using an associated FCoE network, the
Speed/Duplex is always Auto.
Action
Perform delete operations
Associated FCoE Network (VLAN
tagged)
Allows addition of FCoE network. See "Defining an FCoE network (on page
)."
Network Name
Displays the name of the associated FCoE network
VLAN ID
Displays the VLAN ID number
Action
Perform edit or delete operations
Associated Networks (VLAN
tagged)
Network Name
Displays the name of the associated networks
VLAN ID
Displays the VLAN ID number
Native
Select whether native VLAN is enabled (checked) or disabled (unchecked).
Smart Link
Select whether Smart Link is enabled (checked) or disabled (unchecked).
Private Network
Select whether to designate (checked) or not designate (unchecked) the
network as a private network.
Action
Perform edit and delete operations
Connection Mode
Connection mode of the uplink ports for this network. For a description of the
connection modes, see "Defining a shared uplink set." This mode cannot be
changed for shared uplink sets using an associated FCoE network.
LACP Timer
Applicable if Connection Mode is Auto. Shows the LACP timer configuration
for this network. This setting controls the requested frequency of LACP control
messages on a LACP capable interface. The domain default option shows
the current default.
The following table describes the available actions in the Edit Shared Uplink Set screen. Clicking another link
in the pull-down menu or left navigation tree causes current edits that have not been applied to be lost.
- Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric-20.40 F8 Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem