Vc domain mib traps, Vc domain managed status changed traps – HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 37
![background image](/manuals/397170/37/background.png)
Virtual Connect domains 37
Trap name
Trap data
Description
vcModPortBpduLoopCleared port identification
loop status
A network loop condition is cleared on this port. The trap
data indicates the physical port associated with a Flex10
port.
For Flex10 ports, this trap is sent only after all Flex10
ports on a physical port are cleared from a loop
condition.
vcModPortProtectionConditio
nDetected
Port index to the
ifTable (ifIndex)
Port index to the
vcModulePortTable
Port protection status
A port protection condition is detected on this port. If the
new port protection status is a value other than OK, the
port may be disabled to protect the VC module from
further service degradation. Administrative action is
required to recover the port from this condition.
vcModPortProtectionConditio
nCleared
Port index to the
ifTable (ifIndex)
Port index to the
vcModulePortTable
Port protection status
The port is recovered from port protection condition to
normal operational state.
vcSwitchMemParityErrorEvent Error counter
vcSwitchMemParityEr
rorCount
The switch hardware has detected a parity error. The
parity error is automatically corrected.
VC Domain MIB traps
The Virtual Connect vc-domain-mib.mib MIB provides visibility into the various components of a Virtual
Connect Domain.
VC Domain Managed Status Changed traps
This section describes the *ManagedStatus, *Cause, *RootCause, and *ReasonCode OIDs found in each
*ManagedStatusChanged traps in the VC Domain MIB.
The ManagedStatus enumerations (vcDomainManagedStatus, vcEnclosureManagedStatus, and so on) for
all managed status changed objects (vcDomainManagedStatusChanged,
cEnclosureManagedStatusChanged, and so on) are described in the following table.
Managed status
Description
unknown
Indicates the condition of the component could not be determined
normal
Indicates the component is fully functional
warning
Indicates a component threshold has been reached or error condition is imminent
minor
Indicates an error condition exists that has little or no component impact
major
Indicates an error condition exists that significantly impairs the component
critical
Indicates an error condition exists where the component no longer provides service
disabled
Indicates the component is disabled and non-functioning
info
Indicates a non-service affecting condition exists such as initializing components and
system login/logout
•
The Cause string indicates why an object transitioned to the current managed state from the specific
objects perspective. A network failure is an example Cause string.
•
The RootCause string indicates the root causes for an object transitioning managed states. The
RootCause for a network failure could indicate all uplink ports of the network have failed.
- Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric-20.40 F8 Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem