beautypg.com

HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 258

background image

Virtual Connect modules 258

Icon

Operational state Meaning

Corrective action

Unknown

Device operational state cannot be

determined.

Check Onboard Administrator

communication.

Disabled

Device is disabled.

Enable the component in Virtual

Connect Manager.

(blue)

Initializing

Device is initializing.

Wait until initialization is complete.
(This icon should only be seen at

startup.)

(blue)

Unavailable

Device is active but unable to

provide service.

Attempt to re-establish connection.

(yellow)

Degraded

Device is partially operational, but

capacity is lost.

Check and correct the Onboard

Administrator error condition.

(orange)

Misconfigured

Device has a configuration error.

Correct the Virtual Connect Manager

configuration attributes.

(orange)

Incompatible

Device does not match the

configuration.

Remove the incorrect hardware. Insert

the correct module.

(orange)

No communication

Cannot communicate with the

device.

Check the physical connections and IP

address.

Missing

Device is configured but not

accessible.

Insert the correct hardware module.

Failed

Device is not operational because

of an error.

Reset the device or application, or

replace the device.

Interconnect Bay OA Communication Status icon definitions

Icon

Operational state

Meaning

Corrective action

OK

Device is fully operational.

None

Failed

Cannot communicate with the

device.

Do one or more of the following:

Reset the interconnect module.

Check if the physical device is

properly seated in the bay.

Check the IP address.