HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 251
![background image](/manuals/397170/251/background.png)
Virtual Connect modules 251
Port Statistic
Description
IfHCOutMulticastPkts
The total number of packets that higher-level protocols requested be
transmitted, and which were addressed to a multicast address at this
sublayer, including those that were discarded or not sent. For a MAC
layer protocol, this includes both Group and Functional addresses. This
object is a 64-bit version of ifOutMulticastPkts.
IfHCOutBroadcastPckts
The total number of packets that higher-level protocols requested be
transmitted, and which were addressed to a broadcast address at this
sublayer, including those that were discarded or not sent. This object is a
64-bit version of ifOutBroadcastPkts.
cosq
The accumulated dropped packet count of unicast packet of the queue for
the specified port. For VC FlexFabric 10Gb/24-port module and VC
Flex-10 Enet module, the counter includes unicast and multicast data.
cosq
The accumulated transmitted byte count of unicast packets of the queue for
the specified port. For VC FlexFabric 10Gb/24-port module and VC
Flex-10 Enet module, the counter is not supported and the value is 0.
cosq
The accumulated transmitted packet count of unicast packets of the queue
for the specified port. For VC FlexFabric 10Gb/24-port module and VC
Flex-10 Enet module, the counter includes both unicast and multicast data.
*These statistics appear for physical uplink ports, physical downlink ports, and Flex-10 subports. All other statistics only
appear for physical uplink and downlink ports.
Remote Device Information*
Description
remote_type
Type of remote device. Virtual Connect uses this information to configure
the link as an uplink, a stacking link, or to disable. This information is
based on the LLDP data sent by the device to which the port is attached.
remote_discovered_time
Time the remote device was identified, represented in seconds. This
information is based on the LLDP data sent by the device to which the port
is attached.
remote_chassis_id_type
Chassis ID subtype of the remote device
remote_chassis_id
Chassis ID value of the remote device
remote_port_id_type
Port ID subtype of the remote device
remote_port_id
Port ID value of the remote device
remote_port_desc
Port description of the remote device
remote_system_name
System name of the remote device. If the remote device is a VC-Enet
module, remote_system_name is the remote device's VC domain name.
remote_system_desc
Description of the remote system. If the remote device is a VC-Enet module,
remote_system_desc is the module's hardware description and firmware
revision.
remote_system_capabilities
System capabilities of the remote system, for example, repeater, bridge,
or router
remote_mgmt_addr_type
Management address subtype of the remote device, for example, IPv4,
IPv6, or DNS
remote_mgmt_addr
Management address of the remote device
*This information is only available for physical uplink and downlink ports. It is not available for Flex-10 subports.
Pluggable Module Information* Description
identifier
Identifies the type of serial transceiver. The binary values are defined in
SFF-8472 in the Identifier [Address A0h, Byte 0] field. This field displays
an ASCII representation of those binary values.
- Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric-20.40 F8 Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem