Vc module mib traps – HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 36
Virtual Connect domains 36
•
WARNING—The component has a potential problem.
•
INFO—Operational information on the fully functioning component.
•
UNKNOWN—VC Manager has not yet established communication with the component.
•
NORMAL—The component is fully functional.
Trap severities are only supported for VC-Enet or VCM traps.
VC Module MIB traps
The following table lists traps in the VC Module MIB.
Trap name
Trap data
Description
vcModRoleChange
moduleRole
The VCM role of the module has changed.
vcModInputUtilizationUp
port identification
The input line utilization on a port has exceeded its
high-water mark for longer than 30 seconds. port is the
index of the affected port in ifTable.
vcModInputUtilizationDown port identification
The input line utilization on a port has dropped below its
low-water mark for longer than 30 seconds. port is the
index of the affected port in ifTable.
vcModOutputUtilizationUp
port identification
The output line utilization on a port has exceeded its
high-water mark for longer than 30 seconds. port is the
index of the affected port in ifTable.
vcModOutputUtilizationDown port identification
The output line utilization on a port has dropped below its
low-water mark for longer than 30 seconds. port is the
index of the affected port in ifTable.
vcModInputErrorsUp
port identification
ifInErrors
The input error count on a port has exceeded its
high-water mark for longer than the error averaging
period. port is the index of the affected port in
ifTable.
vcModInputErrorsDown
port identification
ifInErrors
The input error count on a port has dropped below its
low-water mark for longer than the error averaging
period. port is the index of the affected port in
ifTable.
vcModOutputErrorsUp
port identification
ifOutErrors
The output error count on a port has exceeded its
high-water mark for longer than the threshold averaging
period. port is the index of the affected port in
ifTable.
vcModOutputErrorsDown
port identification
ifOutErrors
The output error count on a port has dropped below its
low-water mark for longer than 30 seconds. port is the
index of the affected port in ifTable.
vcModPortBpduLoopDetected port identification
loop status
A network loop condition is detected on this port. If the
loop condition is detected on a Flex10 port, the trap data
indicates the physical port associated with the Flex10
port.
If multiple Flex10 ports on a physical port detect a loop
condition, a separate trap is sent for each occurrence of
the loop condition.
- Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric-20.40 F8 Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem