beautypg.com

5 parameters, P325 rotary encoder function, P326 ratio encoder – NORD Drivesystems BU0505 User Manual

Page 95: P327 speed slip error, P328 speed slip delay

background image

5 Parameters

BU 0505 GB-1013

95

P325

Rotary encoder function

(Rotary encoder function)

0 ... 4

{ 0 }

The actual speed list value supplied by an incremental encoder to the FI can be used for various
functions in the FI.

0 = Speed measurement Servo mode, "Servo mode speed measurement": The actual

motor speed list value is used for the FI servo mode. The ISD control cannot be switched
off in this function.

1 = PID actual frequency value: The actual speed of a system is used for speed control.

This function can also be used for controlling a motor with a linear characteristic curve. It
is also possible to use an incremental encoder for speed control which is not mounted
directly onto the motor. P413 – P416 determine the control.

2 = Frequency addition: The determined speed is added to the actual setpoint value.

3 = Frequency subtraction: The determined speed is subtracted from the actual setpoint.

4 = Maximum frequency: The maximum possible output frequency / speed is limited by the

speed of the encoder.

Pos : 162 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P300-P399/ Paramet er P326 – Dr ehg eber Ü bers etz ung @ 0\ mod_1327677354896_388. doc x @ 8842 @ @ 1

P326

Ratio encoder

(Encoder transformation ratio)

0.01 ... 100.00

{ 1.00 }

If the incremental encoder is not mounted directly onto the motor shaft, then the respectively
correct transformation ratio of motor speed to encoder speed must be set.

speed

Encoder

speed

Motor

P326

=

Only when P325 = 1, 2, 3 or 4, therefore not in Servo mode (motor speed control)

Pos : 163 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P300-P399/ Paramet er P327 – Sc hleppfehl er Drehz ahlregl er @ 0\ mod_1327677406270_388. doc x @ 8865 @ @ 1

P327

Speed slip error

(Speed slip error, speed control)

0 ... 3000 rpm

{ 0 }

The limit value for a permitted maximum slip error can be set. If this value is reached, the FI
switches off and indicates error E013.1.

0 = OFF

Only when P325 = 0, therefore in Servo mode (motor speed control)

Pos : 164 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P300-P399/ Paramet er P328 – Verzöger ung Sc hleppf ehl er @ 0\ mod_1327677464020_388. doc x @ 8888 @ @ 1

P328

Speed slip delay

(Speed slip error delay)

0.0 ... 10.0 sec

{ 0.0 }

above SW 2.0

If the permissible speed slip error defined in (P327) is exceeded the error message E013.1 is
suppressed within the time limits which are set here.

0.0 = OFF

Pos : 165 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P300-P399/ Paramet er P330 – R egel verf ahr en PM SM [ SK 54xE] @ 0\ mod_1327677510847_388. doc x @ 8911 @ @ 1