2 assembly and installation – NORD Drivesystems BU0505 User Manual
Page 55
2 Assembly and installation
BU 0505 GB-1013
55
Terminal block X8 – Safe pulse lock (not with 115V devices)
Relevance
SK 540E
SK 545E
√
Terminal X8:
86
87
88
89
VO_S 15V
VO_S 0V
VI_S 0V
VI_S 24V
Name
Terminal Function
[factory setting]
Data
Description / wiring suggestion
Parameter
86
Supply voltage
Details: BU0530!
When setting-up without using a safety
function, wire directly to V_IS 24V.
P420 [-…]
87
Reference potential
88
Reference potential
Details: BU0530!
Fail-safe input
89
Input
'safe pulse block'
Relevance
SK 540E
SK 545E
√
Terminal X8:
86
87
88
89
VO_S 24V
VO_S 0V
VI_S 0V
VI_S 24V
Name
Terminal Function
[factory setting]
Data
Description / wiring suggestion
Parameter
86
Supply voltage
Details: BU0530!
When setting-up without using a safety
function, wire directly to V_IS 24V.
P420 […]
87
Reference potential
88
Reference potential
Details: BU0530!
Fail-safe input
89
Input
'safe pulse block'
Pos : 69 /Anl eitungen/ Elektroni k/FU und Start er/ 2. M ont age und Ins tall ati on/ 2. 10. 5 Elektrischer Ansc hluss St euert eil- St ec kerbl oc k X9 und X10 – C AN / CAN open [SK 54xE] @ 2\ mod_1355475468662_388. doc x @ 52234 @ 5 @ 1