5 parameters, P220 para. identification, P240 emf constant pmsm – NORD Drivesystems BU0505 User Manual
Page 91: P241, Inductivity pmsm, P244 peak current pmsm
5 Parameters
BU 0505 GB-1013
91
P220
Para. identification
(Parameter identification)
P
0 … 2
{ 0 }
For devices with powers up to 7.5 kW, the motor data is automatically determined by the FI via this
parameter. In many cases, a better drive behaviour is possible with the measured motor data.
The identification of all parameters takes some time. Do not switch off the mains voltage during
this time. If unfavourable operating characteristics result after identification, select a suitable motor
in P200 or set the parameters P201 … P208 manually.
0 = No identification
1 = R
S
identification: only the stator resistance (display in P208) is determined by multiple
measurements.
2 = Motor identification :all motor parameters (P202, P203, P206, P208, P209) are
determined. This function can only be used with devices up to 7.5 kW (230 V to 4.0 kW).
Note! Only carry out the identification of motor data when the motor is cold (15 … 25°C) Warming up of
the motor during operation is taken into account.
The FI must be in a “Standby” status For BUS operation, the BUS must be operating without error.
The motor power may only be one power level greater or 3 power levels lower than the nominal
power of the FI.
In order to enable reliable identification, the motor cable length must not exceed 20m.
Before starting the motor identification, the motor data according to the type plate or P200 must be
pre-set. At least the nominal frequency (P201), the nominal speed (P202), the voltage (P204), the
power (P205) and the motor circuit (P207) should be known.
Care must be taken that the connection to the motor is not interrupted during the entire measuring
process.
If the identification cannot be concluded successfully, the error message E019 is generated.
After identification of parameters, P220 is again = 0.
Pos : 142 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P200-P299/ Paramet er P240 – EMK- Kons tant e PMSM [SK 54xE] @ 0\mod_1327590879934_388. doc x @ 8370 @ @ 1
P240
EMF constant PMSM
(EMF constant PMSM)
S
P
0 … 400 V
{ 0 }
The EMF constant describes the self induction voltage of the motor. The value to be set can be
found on the data sheet for the motor or on the type plate and is scaled to 1000 rpm
-1
.
0 = ASM is used, "Asynchronous machine is used": No compensation
Pos : 143 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P200-P299/ Paramet er P241 – Indukti vit aet PMSM [SK 54xE] @ 0\ mod_1327590972170_388.doc x @ 8393 @ @ 1
P241
[-01]
[-02]
Inductivity PMSM
(Inductivity PMSM)
S
P
0.1 ... 200.0 mH
{ all 20.0 }
The typical asymmetric reluctances of the PMSM are compensated with this parameter. The
inductivities can be measured by the frequency inverter (P220)
[-01] = d axis
[-02] = q axis
If q=0 is set, the value of the d axis is adopted automatically.
Pos : 144 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P200-P299/ Paramet er P244 – Spitz ens trom PMSM [ SK 54xE] @ 0\ mod_1327591035576_388.doc x @ 8416 @ @ 1
P244
Peak current PMSM
(Peak current PMSM)
S
P
0.1 … 100.0 A
{ 20.0 }
This parameter contains the peak current of a synchronous motor.
Pos : 145 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P200-P299/ Paramet er P246 – M ass enträg heit PM SM [ SK 54xE] @ 0\ mod_1327591081936_388. doc x @ 8439 @ @ 1