Plug connector block x9 and x10 – can / canopen, Sk 54xe – users manual for frequency inverters – NORD Drivesystems BU0505 User Manual
Page 56
SK 54xE – Users Manual for Frequency Inverters
56
BU 0505 GB-1013
Plug connector block X9 and X10 – CAN / CANopen
Relevance
SK 540E
SK 545E
√
√
Terminals
X9: / X10:
1
2
3
4
5
6
7
8
CAN_H
CAN_L
CAN_GND
nc
nc
CAN_SHD
CAN_GND
CAN_24V
Name
Contact Function
[factory setting]
Data
Description / wiring suggestion
Parameter
1
CAN/CANopen
signal
Baud rate …500kBaud
RJ45 sockets are connected
in parallel internally.
Terminal resistance
R=120
W DIP 2 (see below)
NOTE: To operate
CANbus/CANopen the
interface must be externally
supplied with 24V (capacity
at least 30 mA).
X10
X9
CA
N
_H
CA
N
_L
CA
N
_G
N
D
nc
CA
N
_S
H
LD
CA
N
_G
N
D
nc
C
A
N
_24V
CA
N
_H
CA
N
_L
CA
N
_G
N
D
nc
CA
N
_S
H
LD
CA
N
_G
N
D
nc
C
A
N
_24V
2x RJ45: Pin No. 1 … 8
NOTE: This CANopen interface can be
used for the evaluation of an absolute
encoder. Further details can be found in
manual BU 0510.
Recommendation: Provide strain relief
(e.g. with EMC Kit)
P503
P509
2
3
CAN GND
4
No function
5
6
Cable shield
7
GND/0V
8
External 24VDC
voltage supply
DIP switch 1/2 (top side of frequency inverter)
DIP-1
Termination resistor for RS485 interface
(RJ12); ON = switched in
[Default = "OFF"]
For RS232 communication DIP1 to "OFF"
X11
X10
X9
R
S
485_A
R
S
485_
B
GN
D
T
XD
RX
D
+
5V
1 2
ON
CA
N
_H
CA
N
_L
CA
N
_G
N
D
nc
CA
N
_S
H
L
D
CA
N
_G
N
D
nc
C
A
N
_24V
CA
N
_H
CA
N
_L
CA
N
_G
N
D
nc
CA
N
_S
H
L
D
CA
N
_G
N
D
nc
C
A
N
_24V
RS232/485
DIP CAN/CANopen
DIP 2
Terminal resistor for CAN/CANopen interface
(RJ12); ON = switched in
[Default = "OFF"]