Terminal block x14 – universal encoder interface, 11 colour and contact assignments for encoders, Colour and contact assignments for encoders – NORD Drivesystems BU0505 User Manual
Page 59: 2 assembly and installation
![background image](/manuals/372732/59/background.png)
2 Assembly and installation
BU 0505 GB-1013
59
Terminal block X14 – Universal encoder interface
Relevance
SK 540E
SK 545E
√
√
Terminals X14:
66
65
64
63
DAT-
DAT+
CLK-
CLK+
Name
Terminal Function
[factory setting]
Data
Description / wiring suggestion
Parameter
66
Signal DAT-
(RS485 DAT-)
TTL, RS422
For the connection of SSI, BISS, EnDat
and Hiperface encoders.
P300,
(P604,
however only
for
POSICON)
65
Signal DAT+
(RS485 DAT+)
64
Signal CLK-
For the connection of SSI, BISS and
EnDat encoders.
63
Signal CLK+
Pos : 78 /Anl eitungen/ Elektroni k/FU und Start er/ 2. M ont age und Ins tall ati on/ 2. 10. 5 Elektrischer Ansc hluss St euert eil- Klemmenbl oc k X15 – M ot or PTC und 24V i nput [ SK 54xE] @ 2\ mod_1355475594559_388. doc x @ 52330 @ 5 @ 1
Terminal block X15 – motor PTC and 24V input (above size 8)
Relevance
SK 540E
SK 545E
√
Terminals X15:
38
39
44
40
T1
T2
VI 24V
GND
Name
Terminal Function
[factory setting]
Data
Description / wiring suggestion
Parameter
38
Thermistor input +
EN 60947-8
On: >3.6 kΩ
Off: < 1.65 kΩ
Measurement voltage 5 V
at R <
4 kΩ
The function cannot be switched off, set
a jumper if no PTC is present.
39
Thermistor input -
44
Voltage supply input
24V … 30V
min. 3000mA
Voltage supply for the FI control unit. Is
essential for the function of the
frequency inverter.
40
Reference potential
for digital signals
GND/0V
Reference potential
Pos : 79 /Anl eitungen/ Elektroni k/FU und Start er/ 2. M ont age und Ins tall ati on/ 2. 11 F arb- und Kontaktbel egung für Dr ehg eber [ BU 0500] @ 0\ mod_1325865982124_388. doc x @ 6147 @ 2 @ 1
2.11 Colour and contact assignments for encoders
The incremental encoder connection is an input for a type with two tracks and TTL-compatible signals
for EIA RS 422-compliant drivers. The maximum current consumption of incremental encoders must
not exceed 150 mA.
The pulse number per rotation can be between 500 and 8192 increments. This is set with the normal scaling via parameter
P301 "Incremental encoder pulse number" in the menu group "Control parameters". For cable lengths > 20 m and motor speeds
above 1500 rpm the encoder should not have more than 2048 pulses/revolution.