5 Parameters

BU 0505 GB-1013

133

P546

[-01]

...

[-05]

Digital Bus setpoint

(Function of bus setpoint)

S

P

0 ... 57

{ [-01] = 1 }

all other { 0 }

In this parameter, during bus actuation a function is allocated to the setpoint provided.

NOTE:

The setpoints 4 and 5 must be supported by the relevant bus module. For further
details please refer to the manual for the frequency inverter (P400, P546), the
relevant BUS operating instructions or the manuals BU 0510 / BU0550.

[-01] = Bus setpoint 1

[-02] = Bus setpoint 2

[-03] = Bus setpoint 3

[-04] = Bus setpoint 4

[-05] = Bus setpoint 5

Pos : 309 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P500-P599/ Paramet er P546 – Funkti on Bus-Soll wert e, Ei nst ellungen [ SK 5xxE] @ 2\ mod_1354267859195_388.doc x @ 51897 @ @ 1

0 =

Off

16 = Process controller lead

1 =

Setpoint frequency

17 = BusIO In Bits 0...7

2 =

Torque current limit (P112)

18 = Curve travel calculator

3 =

Actual frequency PID

19 = Set relays, "Output status"

(P434/441/450/455=38)

4 =

Frequency addition

20 = Set analog output (P418=31)

5 =

Frequency subtraction

21 = ... 45 reserved from SK 530E and above

à

BU 0510

6 =

Current limit (P536)

46 = Setpoint Torque processreg., "Setpoint

torque process controller"

7 =

Maximum frequency (P105)

47 = reserved from SK 530E and above

à

BU 0510

8 =

Actual PID frequency limited

48 = Motor temperature (SK 540E and above)

9 =

Actual PID frequency monitored

49 = reserved from SK 540E and above

à

BU 0510

10 = Torque servo mode (P300)

53 = d-correction F process (SK 540E and

above)

11 = Torque precontrol (P214)

54 = d-correction Torque (SK 540E and above)

12 = Reserved

55 = d-correction F+torque (SK 540E and

above)

13 = Multiplication

56 = reserved from SK 540E and above

à

BU 0510

14 = Process controller actual value

57 = reserved from SK 540E and above

à

BU 0510

15 = Process controller setpoint

Scaling details: See Section 8.8

Pos : 312 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P500-P599/ Paramet er P549 – Funkti on Poti-Box @ 0\ mod_1328098389279_388. doc x @ 12008 @ @ 1

P549

Pot Box function

(PotentiometerBox function)

S

0 ... 16

{ 0 }

In this parameter, the setpoint of the PotentiometerBox (SK TU3-POT) is assigned with a
function. (An explanation can be found in the description of P400.)

As of software version 1.7 R0, on setting 4 or 5, the ControlBox or the ParameterBox are also set
to function as suppliers of auxiliary setpoints. (see Section 0)

0 = Off

1 = Setpoint frequency

2 = Torque current limit

3 = Actual frequency PID

4 = Frequency addition

5 = Frequency subtraction

6 = Current limit

7 = Maximum frequency

8 = Actual PID frequency limited

9 = Actual PID frequency monitored

10 = Servo mode torque

11 = Torque precontrol

12 = Reserved

13 = Multiplication

14 = Process controller actual value

15 = Process controller setpoint

16 = Process controller lead

Pos : 313 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P500-P599/ Paramet er P550 – C ontrol Box Auf träge @ 0\mod_1328098468764_388. doc x @ 12031 @ @ 1