beautypg.com

NORD Drivesystems BU0505 User Manual

Page 54

background image

SK 54xE – Users Manual for Frequency Inverters

54

BU 0505 GB-1013

Relevance

SK 540E

SK 545E

Terminals X7:

73

74

26

27

5

7

44*

40

* Terminal 44:

up to Size 4: VI

Size 5 and

above: VO

RS485

+

RS485 -

DIN6

DIN7

DOUT1

DOUT2

V…24V

GND/0V

Name

Terminal Function

[factory setting]

Data

Description / wiring suggestion

Parameter

73

Data cable RS485

Baud rate
9600…38400Baud

Termination resistance
R=120

W

BUS connection parallel to RS485 on
RJ12 plug

NOTE: The termination resistance of
DIP switch 1 (see RJ12/RJ45) can also
be used for terminal 73/74.

P503
P509

74

26

Digital input 6

[no function]

7.5...30V, R

i

=3.3k

W

As described for terminal block X5, DIN1
to DIN5.

Not suitable for the evaluation of a motor
thermistor.

P420 [-06]

27

Digital input 7

[no function]

P420 [-07]

Alternatively:

Output 5 (DOUT3)

[no function]

Digital output

S1 to S4

18-30V, according to VI
24V, max. 20mA
size 5 and above

DOUT1 and DOUT2:

24V, max. 200mA

For inductive loads:
provide protection with a
free-wheeling diode.

The digital input (DIN7) can also be used
as a digital output (DOUT3).

If P434 [-05] and P420 [-07] are
parameterised with functions, a High
signal of the DOUT function results in a
High signal for the DIN function.

P434 [-05]

5

Output 3 (DOUT1)

[no function]

For evaluation in a control system. The
scope of functions corresponds to that of
the relay (P434).

P434 [-03]

7

Output 4 (DOUT2)

[no function]

P434 [-04]

Alternatively:

Digital input 8

[no function] 7.5...30V, R

i

=3.3k

W

The digital output (DOUT2) can also be
used as a digital input (DIN3).

If P434 [-04] and P420 [-10] are
parameterised with functions, a High
signal of the DOUT function results in a
High signal for the DIN function.

P420 [-10]

44

Size 1 to Size 4
VI 24V supply
voltage input

18…30V

at least 800mA (input)

Voltage supply for the FI control unit. Is
essential for the function of the
frequency inverter.

Size 5 and above
VO 24V supply
voltage output

24V ± 25%
max. 200mA (output)

Supply voltage provided by the
frequency inverter for connection to the
digital inputs or the supply of a 10-30V
encoder.

The 24V control voltage is generated by
the FI, however it can also be supplied
via the terminals X12:44/40. Supply via
terminal X7:44 is not possible.

40

Reference potential
for digital signals

0V digital

Pos : 67 /Anl eitungen/ Elektroni k/FU und Start er/ 2. M ont age und Ins tall ati on/ 2. 10. 5 Elektrischer Ansc hluss St euert eil- Klemmenbl oc k X8 – Sic here Pulssperre [SK 54xE] @ 2\ mod_1355475452079_388.doc x @ 52210 @ 5 @ 1