beautypg.com

Table 3: overview of differing hardware features, 1 general – NORD Drivesystems BU0505 User Manual

Page 11

background image

1 General

BU 0505 GB-1013

11

Feature

SK …

50xE

51xE

511E

520E

53xE

54xE

Additional

options

Operating manual

BU 0500

BU 0505

Safe pulse block (STO / SS1)*

x

x

x

x

BU 0530

2 x CANbus/CANopen interfaces via RJ45
plug

x

x

x

x

BU 0060

RS485 interface additionally via terminals

x

x

x

Speed feedback via incremental encoder
input

x

x

x

Integrated “POSICON” positioning control

x

x

BU 0510

CANopen absolute encoder evaluation

x

x

BU 0510

PLC / SPS – functionality

x

BU 0550

Universal encoder interface
(SSI, BISS, Hiperface, EnDat and
SIN/COS)

x

BU 0510

Operation of PMSM
(Permanent Magnet Synchronous Motors)

x

Modbus RTU

x

BU 0050

Number of digital inputs / outputs**

5 / 0

5 / 0

5 / 0

7 / 2

7 / 2

5 / 3 6 / 2

7 / 1

Additional potential-isolated PTC input***

x

Number of analog inputs / outputs

2 / 1

2 / 1

2 / 1

2 / 1

2 / 1

2 / 1

Number of relay messages

2

2

2

2

2

2

* not with 115 V devices
** SK 54xE: 2 I/Os can be variably parameterised as inputs or outputs
*** alternative "thermistor" function on digital input 5 possible (above size 5 an additional thermistor input is available as
standard)

Table 2: Overview of SK 500E performance grading features

Pos : 18 /Anl eitungen/ Elektroni k/FU und Start er/ 1. Allgemei nes/ 1. 1 Ü ber blic k -2- Abweic hende H ardwareeigenschaf ten [BU 0500] @ 1\ mod_1340695009508_388. doc x @ 28170 @ @ 1

Differing hardware features

Version

Description

SK 5xxE

-

-

CP

compared with SK 5xxE

· ColdPlate or external heat sink

SK 5x5E
compared with SK 5x0E

· External 24V supply voltage. Communication with the frequency inverter is

possible even without a power connection

For size 5 and above in
comparison with sizes 1 –
4 (> 4 kW, 230V or
> 11 kW, 400V)

· Additional, separately mounted PTC input (potential isolated)
· External 24V supply voltage with automatic switchover to the internal 24V low

voltage generator on failure of the external control voltage.

· Processing of both bipolar and analog signals

· 2 x CANbus/CANopen interfaces via RJ45 plug as standard

Table 3: Overview of differing hardware features

Pos : 19 /Anl eitungen/ Elektroni k/FU und Start er/ 1. Allgemei nes/ 1. 2 Lief erung @ 0\ mod_1325780242208_388.doc x @ 5339 @ 2 @