Motor data / characteristic curve parameters, 5 parameters, P200 motor list – NORD Drivesystems BU0505 User Manual
Page 85
5 Parameters
BU 0505 GB-1013
85
Pos : 119 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ P2xx M ot ordat en / Kennlinienpar ameter @ 0\ mod_1327588046860_388. doc x @ 7838 @ 5 @ 1
Motor data / Characteristic curve parameters
Parameter
{factory setting}
Setting value / Description / Note
Supervisor
Parameter set
Pos : 120 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P200-P299/ Paramet er P200 – M ot orlist e @ 0\ mod_1327588261094_388.doc x @ 7861 @ @ 1
P200
Motor list
(Motor list)
P
0 ... 73
{ 0 }
The factory settings for the motor data can be edited with this parameter. The factory setting in
parameters P201...P209 is a 4-pole IE-1 DS standard motor with the nominal FI power setting.
By selecting one of the possible digits and pressing the ENTER key, all motor parameters
(P201…P209) are adjusted to the selected standard power. The basis for the motor data is a 4-pole
DS standard motor
0 = No change to data
1 = No motor: In this setting, the FI operates without current control, slip compensation and pre-
magnetising time, and is therefore not recommended for motor applications. Possible
applications are induction furnaces or other applications with coils and transformers. The
following motor data is set here: 50.0Hz / 1500rpm / 15.0A / 400V / 0.00kW / cos
j=0.90 /
Star / R
S
0.01
W / I
LEER
6.5A
2 = 0.25kW 230V
3 = 0.33 Hp 230V
4 = 0.25kW 400V
5 = 0.33 Hp 460V
6 = 0.37kW 230V
7 = 0.50 Hp 230V
8 = 0.37kW 400V
9 = 0.50 Hp 460V
10 = 0.55kW 230V
11 = 0.75 Hp 230V
12 = 0.55kW 400V
13 = 0.75 Hp 460V
14 = 0.75 Hp 230V
15 = 1.0 Hp 230V
16 = 0.75 Hp 400V
17 = 1.0 Hp 460V
18 = 1.1 kW 230V
19 = 1.5 Hp 230V
20 = 1.1 kW 400V
21 = 1.5 Hp 460V
22 = 1.5 Hp 230V
23 = 2.0 Hp 230V
24 = 1.5 Hp 400V
25 = 2.0 Hp 460V
26 = 2.2 kW 230V
27 = 3.0 Hp 230V
28 = 2.2 kW 400V
29 = 3.0 Hp 460V
30 = 3.0 Hp 230V
31 = 3.0 Hp 400V
32 = 4.0 kW 230V
33 = 5.0 PS 230V
34 = 4.0 kW 400V
35 = 5.0 PS 460V
36 = 5.5 kW 230V
37 = 7.5 PS 230V
38 = 5.5 kW 400V
39 = 7.5 PS 460V
40 = 7.5 kW 230V
41 = 10.0 PS 230V
42 = 7.5 kW 400V
43 = 10.0 PS 460V
44 = 11.0 kW 400V
45 = 15.0 PS 460V
46 = 15.0 kW 400V
47 = 20.0 PS 460V
48 = 18.5 kW 400V
49 = 25.0 PS 460V
50 = 22.0 kW 400V
51 = 30.0 PS 460V
52 = 30.0 kW 400V
53 = 40.0 PS 460V
54 = 37.0 kW 400V
55 = 50.0 PS 460V
56 = 45.0 kW 400V
57 = 60.0 PS 460V
58 = 55.0 kW 400V
59 = 75.0 PS 460V
60 = 75.0 kW 400V
61 = 100.0 PS 460V
62 = 90.0 kW 400V
63 = 120.0 PS 460V
64 = 110.0 kW 400V
65 = 150.0 PS 460V
66 = 132.0 kW 400V
67 = 180.0 PS 460V
68 = 160.0 kW 400V
69 = 220.0 PS 460V
70 = 200.0 kW 400V
71 = 270.0 PS 460V
72 = 250.0 kW 400V
73 = 340.0 PS 460V
NOTE:
As P200 returns to = 0 after the input confirmation, the control of the set motor can be implemented
via parameter P205.
Information
IE2 motors
For the use of IE2 motors, after the selection of an IE1 motor (P200) the motor data in P201 ...
P209 must be adapted to the data on the motor type plate.
Pos : 121 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P200-P299/ Paramet er P201 – M ot or N ennfr equenz @ 0\ mod_1327588385923_388. doc x @ 7884 @ @ 1