beautypg.com

NORD Drivesystems BU0505 User Manual

Page 160

background image

SK 54xE – Users Manual for Frequency Inverters

160

BU 0505 GB-1013

FI type (size 5/ 6 / 7):

SK 5xxE…

-551-323-A

-751-323-A

-112-323-A

-152-323-A

-182-323-A

Nominal motor power

(4-pole standard motor)

230V

5.5 kW

7.5 kW

11.0 kW

15.0 kW

18.5 kW

240V

7½ hp

10 hp

15 hp

20 hp

25 hp

Input

Mains voltage

3~ 230V

3 AC 200 … 240V,

± 10%, 47 … 63Hz

Input current

rms

30.8 A

39.2 A

64.4 A

84.0 A

102 A

FLA

30.8 A

39.2 A

58.8 A

75.6 A

95.2 A

Recommended
mains fuse*

1 AC slow-acting

30hp

40 A

60 A

100 A

100 A

CB

35 A

50 A

60 A

100 A

100 A

Permissible mains
fuses for UL*

Fuse, 300V

30hp

40 A

60 A

100 A

100 A

Bussmann

FRS-R-30

FRS-R-40

FRS-R-60

FRS-R-100

FRS-R-100

CB

60 A

60 A

60 A

100 A

100 A

O

ut

put

Output voltage

3~ 230V

3 AC 0 - Mains voltage

Output current

rms

22.0 A

28.0 A

46.0 A

60.0 A

73.0 A

FLA

22.0 A

28.0 A

42.0 A

54.0 A

68.0 A

Min. braking resistor

Accessories

19

W

14

W

10

W

7

W

6

W

Type of ventilation

Fan cooling, temperature-controlled Switching thresholds:

ON= 57°C OFF=47°C

Weight

Approx. [kg]

8

10.3

15

* see also Section 1.5.2. Fuses: High-Interrupting Capacity, Current Limiting Classes (z.B. R, J, …), circuit breaker (CB): Inverse Time Trip Type

Pos : 440 /Anleit ungen/7. / 8. Technisc he Daten [BU 0500/ BU 0200] /SK 5xxE/ 7. 2.3 El ektrisc he Daten 400V @ 0\ mod_1328183463001_388.doc x @ 14075 @ 3 @ 1