Pos : 349 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P722 – Akt uelle Spannung @ 0\ mod_1328173115169_388. doc x @ 12847 @ @ 1
P722
Current voltage
(Actual voltage)
0 ... 500 V
Displays the actual AC voltage supplied by the FI output.
Pos : 350 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P723 – Akt uelle Spannungs komponente dU @ 0\ mod_1328173153339_388. doc x @ 12870 @ @ 1
P723
Voltage -d
(Actual voltage component dU)
S
-500 ... 500 V
Displays the actual field voltage component.
Pos : 351 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P724 – Akt uelle Spannungs komponente Uq @ 0\ mod_1328173194227_388. doc x @ 12893 @ @ 1
P724
Voltage -q
(Actual voltage component Uq)
S
-500 ... 500 V
Displays the actual torque voltage component.
Pos : 352 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P725 – Akt ueller c os phi @ 0\ mod_1328173237475_388.doc x @ 12916 @ @ 1
P725
Current Cos phi
(Actual cosj)
0.00 ... 1.00
Displays the actual calculated cos
j of the drive.
Pos : 353 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P726 – Sc hei nleis tung @ 0\ mod_1328173288066_388.doc x @ 12939 @ @ 1
P726
Apparent power
(Apparent power)
0.00 ... 300.00 kVA
Displays the actual calculated apparent power. The basis for calculation are the motor data
P201...P209.
Pos : 354 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P727 – M ec hanisc he Leist ung @ 0\ mod_1328173332220_388. doc x @ 12962 @ @ 1
P727
Mechanical power
(Mechanical power)
-99.99 ... 99.99 kW
Displays the actual calculated effective power of the motor. Basis for calculation are the motor
data P201...P209.
Pos : 355 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P728 – N et zspannung @ 0\ mod_1328173378202_388. doc x @ 12985 @ @ 1
P728
Input voltage
(Mains voltage)
0 ... 1000 V
Displays the actual mains voltage at the FI input.
Pos : 356 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P729 – Dr ehmoment @ 0\ mod_1328173426559_388.doc x @ 13008 @ @ 1
P729
Torque
(Torque)
-400 ... 400 %
Displays the actual calculated torque. Basis for calculation are the motor data P201...P209.