DATA RECORDER CONFIGURATION SUB-MENU SCREENS:
No Recorder
Warning
If the Recorder Configuration menu is entered on an instrument without this
option fitted.
Recording In
Progress Warning
A warning if recording when attempting to enter recorder configuration. -
Access to the configuration is denied unless the recording is paused.
Pause (Override
Trigger)
Select No to continue recording or Yes to enter recorder configuration.
Note: Recording is paused until recorder configuration is
completed. It restarts automatically on exit from this menu.
Recorder Status
Information
Current information about the data recorder feature, including if a recording
is in progress (Recording or Stopped); the recording mode (FIFO or Record
Until Memory Is Used); a % memory use bar-graph and the estimated
available time remaining based on the data selected and memory left.
If the alarm status is recorded and is likely to change often, take this into
account when determining if there is sufficient memory available.
Icons are displayed for active recording triggers. If any trigger is active, the
selected data will be recorded.
Manual Record
Digital Input
Profile Record
Alarm Record
- see the Data Recorder in section on page 97
Recorder Mode
Choose Record Until Memory Used (stops recording when full) or
Continuous FIFO (First In - First Out).
Caution:
A FIFO recording will overwrite previous recordings in
memory, starting with the oldest data first. Download the previous
data before selecting this option.
Recording Sample
Interval
Recording of the selected data will happen once every sample interval.
From every: 1; 2; 5; 10; 15; 30 Seconds, or 1; 2; 5; 10; 15; 30 Minutes.
- The recording interval does not affect Trend View sample rates.
Note: Shorter intervals reduce the possible recording duration.
Recorder Auto
Trigger
Automatic recording triggers. From: None; On Alarm; During Profile and
Alarm or Profile. Data is recorded if any trigger is active (including a digital
input or manual recording start).
Trigger On Alarms
Any combination of alarms 1 to 7 can be set to trigger a recording (TRG) or
not (OFF). If any alarm set to TRG becomes active, the alarm recording
trigger will also activate.
Loop 1 Values To
Record
Any combination of loop 1 values can be recorded from: Process Variable;
Maximum or Minimum PV (since the previous sample was taken); Setpoint;
Primary Power, Secondary Power. Set to Record (REC) or not (OFF).
Note: Recording more parameters reduces the possible
recording duration.
Loop 2 Values To
Record
Any combination of loop 2 values can be recorded from: Process Variable;
Maximum or Minimum PV (since the previous sample was taken); Setpoint;
Primary Power, Secondary Power. Set to Record (REC) or not (OFF).
Note: Recording more parameters reduces the possible
recording duration.
Other Values To
Record
If required, select to record the value of auxiliary input A.