beautypg.com

West Control Solutions Pro-EC44 User Manual

Page 162

background image

Pro-EC44 2-Loop Graphical Profile Controller & Recorder

Pro-EC44 Product Manual - 59540-1 October 2013

Page 155

Loop 1 Valve Open Limit

Loop 1 Maximum Valve Position

Dec

4377

20761 41522

RW

Maximum position to drive valve in VMD Mode.

From 0.0% to the valve open limit-1%

Hex

1119

5119

A232

Loop 1 PID Set Select

Value

Loop 1 PID Set Selection

Dec

4367

20751 41502

RW

0

PID Set 1

Hex

110F

510F

A21E

1

Gain Schedule Selected by SP

2

Gain Schedule Selected by PV

3

PID Set 2

4

PID Set 3

5

PID Set 4

6

PID Set 5

PID Set 2 - Primary Prop Band

PID Set 2 Primary Proportional Band For Loop 1

Dec

4347

20731 41462

RW

Primary Proportional Band for Gain Set 2.

1 display unit to 9999 units,

but limited to 10 x scaled input span. 0 = On-Off control

Hex

10FB

50FB

A1F6

PID Set 2 - Secondary Prop Band

PID Set 2 Secondary Proportional Band For Loop1

Dec

4348

20732 41464

RW

Secondary Proportional Band for Gain Set 2.

1 display unit to 9999 units,

but limited to 10 x scaled input span. 0 = On-Off control

Hex

10FC

50FC

A1F8

PID Set 2 - Integral Time

PID Set 2 - Integral Time For Loop 1

Dec

4349

20733 41466

RW

Gain Set 2 integral time constant for loop 1

0.1 to 5999 Seconds. 0 or 6000 = OFF

Hex

10FD

50FD

A1FA

PID Set 2 - Derivative Time

PID Set 2 - Derivative Time For Loop 1

Dec

4350

20734 41468

RW

Gain Set 2 derivative time constant for loop 1

0.1 to 5999 Seconds. 0 or 6000 = OFF

Hex

10FE

50FE

A1FC

PID Set 2 - Overlap/Deadband

PID Set 2 - Overlap/Deadband For Loop 1

Dec

4351

20735 41470

RW

PID Set 2 overlap (+ve) or deadband (-ve) between primary &

secondary prop bands. In display units - limited to 20% of the

combined band width.

Hex

10FF

50FF

A1FE

PID Set 2 - On/Off Differential

PID Set 2 - On/Off Differential For Loop 1

Dec

4378

20762 41524

RW

The on-off control hysteresis (deadband) for PID Set 2.

1 to 300 display units, centred about the setpoint.

Hex

111A

511A

A234

PID Set 3 - Primary Prop Band

PID Set 3 Primary Proportional Band For Loop 1

Dec

4352

20736 41472

RW

Primary Proportional Band for Gain Set 3.

1 display unit to 9999 units,

but limited to 10 x scaled input span. 0 = On-Off control

Hex

1100

5100

A200

PID Set 3 - Secondary Prop Band

PID Set 3 Secondary Proportional Band For Loop 1

Dec

4353

20737 41474

RW

Secondary Proportional Band for Gain Set 3.

1 display unit to 9999 units,

but limited to 10 x scaled input span. 0 = On-Off control

Hex

1101

5101

A202

PID Set 3 - Integral Time

PID Set 3 - Integral Time For Loop 1

Dec

4354

20738 41476

RW

Gain Set 3 integral time constant for loop 1

0.1 to 5999 Seconds. 0 or 6000 = OFF

Hex

1102

5102

A204

PID Set 3 - Derivative Time

PID Set 3 - Derivative Time For Loop 1

Dec

4355

20739 41478

RW

Gain Set 3 derivative time constant for loop 1

0.1 to 5999 Seconds. 0 or 6000 = OFF

Hex

1103

5103

A206

PID Set 3 - Overlap/Deadband

PID Set 3 - Overlap/Deadband For Loop 1

Dec

4356

20740 41480

RW

PID Set 3 overlap (+ve) or deadband (-ve) between primary &

secondary prop bands. In display units - limited to 20% of the

combined band width.

Hex

1104

5104

A208

This manual is related to the following products: