3. Physically connect the HelixNet Partyline and Tempest systems.


Powering the connection:
You must power the connection between the systems using either a dedicated power supply
(such as the PK-7, PS-702, or PS-704), or a powered Encore Main Station (such as the MS-702
or MS-704).

Tip:

For more information about the dPK-7 or PS-70x power supply devices from Clear-Com,

see

http://www.clearcom.com/product/partyline/power-supplies


Connecting to Tempest:
You can use standard microphone cable or CAT5 cable types to connect the HMS-4X Main
Station to the Tempest Basestation. 3-pin XLR connectors are located:

• On the HMS-4X Main Station two-wire interface module.

• On the back panel (rear) of the Tempest Basestation.

Tip:

Tempest provides two-wire input/output gain adjustments, and can be utilized to either

balance the gains between HelixNet and Tempest or connect two-wire system interfaces through
a Tempest base station.

4. Adjust the In / Out volume level controls [ ] on the Tempest Basestation.


The In / Out volume levels have the following ranges:

Volume level

Range

In

-18dB - +4dB

Out

-18dB - +4dB

Table 39: Tempest BaseStation In / Out volume levels

For more information, see your Tempest reference manual.

Tip:

To optimize audio quality, you may also want to adjust the Audio Settings on the

HMS-4X Main Station. For more information, see 5.2 Configuring the Audio settings.