9.4.2 Quick reference: Two-wire connection to CellCom / FreeSpeak

Figure 21: Two-wire connection to CellCom / FreeSpeak

HMS-4X Main Station 2W

Power

supply

Or

Encore Main Station

(MS-70x)

CellCom / FreeSpeak Basestation

Standard mic cable / CAT-5

3-pin XLR connectors

Line must be powered

(HMS-4X 2W module appears as unpowered

beltpack / remote station to CellCom / FreeSpeak).

Configure the 2W module

Configure the port as Clear-Com

Enable auto-nulling

2W

Connect to CH-A or CH-B connectors

Enable CH-A or CH-B. Check that

channel LED is lit

red

Enable auto-nulling

Two-wire connection to CellCom / FreeSpeak