Menu 4 (Last )
Diagnostics
Hardware
Main PCB
Part: [Part_Number]
Revision: [Revision]
Serial number: [Serial number]
Slot 1 PCB
Slot 2 PCB
Slot 3 PCB
Temperature
Sensor 1
Temperature in °C.
Note:
Single fan on if any sensor > 60°C.
Double fan on if any sensor > 65°C.
Double fan off if < 55°C / single fan off if < 50°C.
Sensor 2
Sensor 3
Powerlines
Powerline 1
Powerline 2
Status: [OK or BUSY (according to responses to MME
requests)].
DMC:[MAC of powerline modem]
HMC: [MAC of local blackfin processor]
Beltpacks: [# of beltpacks detected by powerline modem]
Collision rate: [Percentage (0% when operating normally)]
Error rate: [Percentage (0% when operating normally)]
Volts: [Voltage]
Keysets
Keyset 1
Keyset 2
Keyset 3
Keyset 4
Name: Channel name
Talkers: Number of talkers on party line
Beltpacks: Number of beltpacks listening on party line
Main Stations: Number of Main Stations listening
2-Wire: Number of 2-Wire ports listening
4-Wire: Number of 4-Wire ports listening
Table 65: HMS-4X Main Station menu map