9.2.2 Quick reference: Two-wire connection to RTS 2W system
Figure 18: Two-wire connection to RTS 2W system
HMS-4X Main Station 2W
Power
supply
Or
Encore Main Station
(MS-70x)
RTS Intercom Station (MCE325)
Standard microphone cable
3-pin XLR connectors
Line must be powered (HMS-4X 2W module appears as
unpowered beltpack / remote station to RTS system)
Configure the 2W module
Configure the port as RTS
Enable auto-nulling
2W
Enable connected channel (on MCE325, CH-A or CH-B)
Enable nulling / auto-nulling
Two-wire connection to RTS (Telex) 2W system
3
1
2
Grd
Pwr or Pwr
+ Audio
Audio (Not if pin 2
Pwr + Audio)
RTS pinout
options in
software:
You can:
Select different RTS options for A and B
connectors (so pin 2 for audio for A, pin 3 for
audio for B)
Configure Clear-Com 2W on one connector,
RTS on the other connector
91