5 four-wire connection to eclipse, Four-wire connection to eclipse – Clear-Com HLI-FBS User Manual
Page 116
9.6.5 Four-wire connection to Eclipse
To connect your HelixNet Partyline system to an Eclipse Median, using a four-wire connection:
1. On the HMS-4X Main Station, configure the Module Settings for the four-wire interface module
For the procedure, see
5.6.1 Configuring a Four-wire interface module.
2. Connect the HMS-4X Main Station directly to the MVX-A16 card (the 16 port audio and data card
set) with standard CAT5 cable.
Important note:
For pinout information for the two systems, see the quick reference diagram in
9.6.4 Quick reference: Four-wire connection to Eclipse.
RJ45 connectors are located:
• On the HMS-4X Main Station four-wire interface module.
• On the rear panel of the MVX-A16 card.
Tip:
To optimize audio quality, you may want to adjust the Audio Settings on the
HMS-4X Main Station. For more information, see 5.2 Configuring the Audio settings
Tip:
For more information about managing the HelixNet to Eclipse connection in ECS, see your
ECS documentation (including ECS Help).
114
HelixNet Partyline User Guide