Clear-Com HLI-FBS User Manual
Page 14
I
LEDs for lines 1 and 2 (partylines). The LEDs indicate the status of the intercom
circuit powering. When an LED is lit:
•
Green
, the line is functioning.
•
Amber
, the line is busy.
•
Red
, there is an error or fault on the line.
If there is a fault on a powerline output, the Line STATUS indicator for that channel will
turn off and the red FAULT indicator will flash. Possible causes of a fault include
overvoltage, overcurrent, short circuit to ground or severe brown-outs.
J
Loudspeaker. When a headset is connected [
B
] and selected [
E
], loudspeaker
output is diverted to the headphones.
K
Program feed audio level rotary control [Program].
To increase the volume of the program feed to the loudspeaker / headphones, turn
clockwise (up to 360°).
To decrease the volume, turn anticlockwise (up to 360°). As you increase or decrease
the volume, the level control LEDs pass through a range of indicator colors:
LED color
Volume level
Green
Low
Amber
/
Green
Low / Medium
Amber
Medium
Red
/
Amber
Medium / High
Red
High
Table 3: Volume Indicator colors
L
Loudspeaker / Headphone audio level rotary control [Main]. To increase the volume
to the loudspeaker / headphones, turn clockwise (up to 360°). To decrease the volume,
turn anticlockwise (up to 360°).
As you increase or decrease the volume, the level control LEDs pass through a range of
indicator colors. For more information, see Table 3: Volume Indicator colors above
[
K
].
M
Remote Mic Kill [RMK]. Press to:
• Send a message to all connected HelixNet HBP-2X beltpacks to deselect any
latched keyset Talk routes.
• Turn off any latched Talk routes on connected analog partyline beltpacks.
14
HelixNet Partyline User Guide