3-35

ISM 824 Integration Scaling Multiswitcher • Operation and Setup

4

.

Press Next to enter the next submenu, Sync Polarity. Within this submenu,

the Sync Polarity can be set (H- V-, H+ V-, H+ V+, or H- V+).

Rotate either front panel encoder to adjust the polarity setting. The table

below gives the recommended settings.

Output Configuration (Scaler boards)

Output Format

Sync Polarity

RGBHV

H- V-

RGBS

H- V+

RGsB

H+ V-

YUV Bi-Level

H+ V+

YUV Tri-Level

Figure 3-47 — Universal RGB sync polarity table

5

.

Press Next to return to the upper level Output Config menu.

6

.

Press Menu to go to the next submenu (User Presets).

User Presets submenu

Within this submenu, up to 3 presets can be saved or erased.

1

.

From the Output Config menu, press Menu to enter the User Presets

submenu.

2

.

Press Next to go to the Save Preset menu.

Rotate either front panel encoder to select the preset (1, 2 or 3) to save the

current settings. Default setting is N/A.

3

.

Press Next to go to the Save Preset menu.

Rotate either front panel encoder to select the preset to be erased (1, 2 or 3).

Default setting is N/A.

4

.

Press Next to return to the User Preset menu.

5

.

Press Menu to go to the next submenu (Advanced Config).

Recall a User Preset

1

.

Press the Esc button to clear all active menus and reset the LCD to default

menu cycle.

2

.

Make an input tie to the desired scaler output to recall any one of the three

saved presets, numbered 1 to 3.

3

.

Press the output button. The LCD displays the message shown below.

Output Recalls

User Preset

4

.

Press the output button to cycle through the saved output presets (1, 2, or 3).

User Preset #2

Recalled

5

.

If no presets were saved previously, the following message is displayed.

No Valid User

Presets Found