Exchange, Time comp (time compression/expansion), Parameter list – Yamaha AW2400 User Manual
Page 141
List of editing command
141
AW2400 Owner’s Manual
Tr
ac
k oper
ations and editing
15
Exchanges data between the specified tracks.
*1. The items that you can select in
D
To TR (copy-destination track)
will depend on the
A
From TR (copy-source track) setting.
If
A
From TR is a single audio track 1–24, you can select only a sin-
gle audio track 1–24.
If
A
From TR is ST or 1&2–23&24 (a pair of adjacent audio tracks),
you can select only 1&2–23&24 (a pair of adjacent audio tracks).
Adjusts the length of the specified region of an audio
track, without changing the pitch.
● If you set Ratio = 50%
● If you set Ratio = 200%
Parameter
Range
Explanation
A
From TR
1–24
A single audio track
1&2–23&24
A pair of adjacent odd-numbered/
even-numbered audio tracks
ST
The stereo track
B
From V.TR
1–8
Exchange-source virtual track
number
C
Name
Up to eight
alphanumeric
characters
Exchange-source virtual track
name (display only)
D
To TR
*1
1–24
A single audio track
1&2–23&24
A pair of adjacent odd-numbered/
even-numbered audio tracks
E
To V.TR
1–8
Exchange-destination virtual track
number
F
Name
Up to eight
alphanumeric
characters
Exchange-destination virtual track
name (display only)
EXCHANGE
C
A
B
D
E
F
EXCHANGE
From
Track
To
Track
From
Track
To
Track
1 2 3 4 5 6
A B C D E F
1 2 3 4 5 6
A B C D E F
■ Parameter list
• The track names will not be exchanged.
NOTE
Parameter
Range
Explanation
A
From TR
1–24
A single audio track
1&2–23&24
A pair of adjacent odd-numbered/
even-numbered audio tracks
ST
The stereo track
B
From V.TR
1–8
Virtual track number
C
From Start
Specify a point
Beginning of the edited region
D
From End
Specify a point
End of the edited region
E
TO END
Specify a point
Specify the length to which the
selected region will be com-
pressed or expanded
F
To Ratio
50–200%
Specify the percentage by which
the selected region will be com-
pressed or expanded
TIME COMP
(Time Compression/Expansion)
E
F
A
C
D
B
TIME
COMP/EXP
From End
1 2 3 4 A B C D
1
2 3 4
A B C D
From Start
To END
TIME
COMP/EXP
From End
1 2 3 4 A B C D
1
C D
From Start
To END
2 3
4
■ Parameter list
• TO END and To Ratio are linked, so that editing one field will
cause the other field to change.
• You cannot set TO END or To Ratio to a value that would cause
the ratio to exceed 50–200 percent.
• From Start value and From End value must be at least 45 msec
apart. These cannot be set to a shorter interval.
NOTE