Chapter 6 – Color Workflow
If you selected
Automatic as the Screening Method in Step 1 of the wizard, you
need to calibrate the Spire CX260 using two charts. Step 2 of the Calibration
Wizard appears as follows:
11. Press and hold the button on the side, and align the head with the cyan arrow’s
tip. The arrow is to the left of the cyan column on the Image Density Calibration
chart. Its tip intersects the semi-dotted line.
12. Sweep the Eye-One spectrophotometer across the cyan column.
A check mark appears over the cyan icon and instructions appear for the next
sweep, this time for the magenta column.
13. After each color sweep, wait for the check mark to appear next to the
appropriate icon and follow the instructions as listed.
When all of the separation columns have been successfully scanned, a check
mark appears next to all icons.
Note: Ensure that the separation columns on the chart
are scanned in the
order they appear in the icons:
Cyan > Magenta > Yellow > Black
.
Notes:
•
If at any stage the scanning has not been completed properly, click
Reset
and scan again.
•
If an error occurs while you are scanning the chart, an alert message
appears. Click
OK
and re-scan the charts.
•
If you selected
Automatic
as the
Screening Method
in Step 1 of the
wizard, repeat steps 11-13 for the Text/Line Art chart.