Intel NETWORK PROCESSOR IXP2800 User Manual
Page 400
400
Hardware Reference Manual
Intel
®
IXP2800 Network Processor
Performance Monitor Unit
97
Rx null autopush
P_CLK
pulse
separate
98
Tx skip
P_CLK
pulse
separate
An mpacket was dropped due to the
Tx_Skip bit being set in the Transmit Control
Word.
99
SF_CRDY
P_CLK
level
separate
Only valid in CSIX receive mode and
indicates how much of the time the switch
fabric is able to receive control CFrames.
100
SF_DRDY
P_CLK
level
separate
Only valid in CSIX receive mode and
indicates how much of the time the switch
fabric is able to receive data CFrames.
101
TM_CRDY
P_CLK
level
separate
Only valid in CSIX receive mode; indicates
how much of the time the egress processor
is able to receive control CFrames.
102
TM_DRDY
P_CLK
level
separate
Only valid in CSIX receive mode; indicates
how much of the time the egress processor
is able to receive data CFrames.
103
FCIFIFO enqueue
P_CLK
pulse
separate
104
FCIFIFO dequeue
P_CLK
pulse
separate
105
FCIFIFO error
P_CLK
pulse
separate
Indicates that a bad CFrame was received
on the CBus (horizontal or vertical parity
error, premature RxSOF); only valid in CSIX
transmit mode.
106
FCIFIFO synchronizing
FIFO error
P_CLK
pulse
separate
Indicates that the CBus ingress logic
encountered a FCIFIFO full condition while
enqueueing a CFrame into FCIFIFO.
107
Vertical parity error
P_CLK
pulse
separate
Only valid in CSIX receive mode.
108
Horizontal parity
P_CLK
pulse
separate
Only valid in CSIX receive mode.
109
Dip 4 Parity Error
P_CLK
pulse
separate
Only valid in SPI-4 receive mode.
110
Dip 2 Parity Error
P_CLK
pulse
separate
Only valid in SPI-4 receive mode.
111
reserved
112
CSIX DATA receive active
MR_CLK
level
separate
Indicates a valid CSIX DATA CFRAME
received on the RX_DATA bus and may be
used to measure bus utilization; the active
signal from the MR_CLK domain is
synchronized; as such, it yields an
approximate value.
113
CSIX CONTROL
receive active
MR_CLK
level
separate
Indicates a valid CSIX CONTROL CFRAME
received on the RX_DATA bus and may be
used to measure bus utilization; the active
signal from the MR_CLK domain is
synchronized; as such, it yields an
approximate value.
114
SPI-4 receive active
MR_CLK
level
separate
Indicates a valid SPI-4 Packet received on
the RX_DATA bus and may be used to
measure bus utilization; the active signal
from the MR_CLK domain is synchronized;
as such, it yields an approximate value.
Table 157. IXP2800 Network Processor MSF PMU Event List (Sheet 5 of 6)