Configure readers, Sensor, Input types – Interlogix TruPortal User Manual
Page 44
Configuring the System
32
TruPortal Software User Guide
Input Types
NO (Normally Open)
The sensor switch is normally open.
NC (Normally Closed)
The sensor switch is normally closed.
Unsupervised
The circuit is not wired with a continuity circuit to detect tampering.
Supervised
The circuit is wired with a continuity circuit to detect tampering.
Note:
For IPSDCs, refer to the IP-based Single Door Controller Quick Reference for
information about how to configure the switch settings based on input type selection.
Configure Readers
1.
Select System Administration > Devices.
2.
Expand the tree below the System Controller.
3.
Expand the tree below the Door Controller.
4.
Expand the tree below the Door.
5.
Select the Reader to configure.
6.
Select an Access Method.
•
7.
Select a Linked Camera if one is position to watch this door and reader.
8.
Click [Accept Changes].
9.
Repeat for other readers.
Reader Configuration Options
Credential Only
A person need only present a valid credential (ID badge) to gain access.
Credential and PIN
A person needs to present a valid credential and enter a Personal Identification Number (PIN) to
gain access. This prevents someone gaining access with a stolen or found credential. Some
facilities use Credential Only during the day and Credential and PIN after hours, when the
facility is empty.
PIN Only
A person need only enter a valid Personal Identification Number (PIN) to gain access.
PIN or Credential
A person needs to present either a valid credential or enter a Personal Identification Number
(PIN) to gain access.