Figure4.4 webbios logical drive screen, Webbios logical drive screen – Avago Technologies MegaRAID SATA 150-4 (523) User Manual
Page 94
4-10
WebBIOS Configuration Utility
Version 2.0
Copyright © 2003–2006 by LSI Logic Corporation. All rights reserved.
Figure 4.4
WebBIOS Logical Drive Screen
4.4.6.1
Initialization
This option initializes the selected logical drive by writing zeroes to the
entire volume (if fast initialization is selected, zeroes are written to the
first sector only).
Note:
After you define a logical drive, WebBIOS asks you for
initialization of the logical drive. LSI does not recommended
choosing to initialize, as a background initialization may run.
4.4.6.2
Check Consistency
This option verifies that the redundancy data is correct and available for
arrays using RAID 1, 5, 10, or 50. If a difference in the data is found, the
MegaRAID adapter assumes that the data is accurate and automatically
corrects the parity value.