Section 5.3.1.6, “installing the – Avago Technologies MegaRAID SATA 150-4 (523) User Manual
Page 112
5-10
Start the Power Console Plus Utility
Version 2.0
Copyright © 2003–2006 by LSI Logic Corporation. All rights reserved.
Step 4.
Pull down the Security menu in File Manager and select
PERMISSIONS.
Step 5.
When the Permission dialog box appears, assign the LIST
permission to all groups except Administrator, Backup
Operators, System, and Creator Owner.
Step 6.
In the Permission dialog box, select Replace Permissions On
Subdirectories.
Step 7.
Select OK.
Step 8.
Exit File Manager.
Step 9.
Log in as a guest and verify the permission changes.
Step 10. Proceed to
Section 5.3.1.6, “Installing the MegaService Monitor.”
5.3.1.6
Installing the MegaService Monitor
The MegaService Monitor installation uses the Power Console Plus
Installshield. The following steps provide detailed installation instructions.
Step 1.
Insert the first Power Console Plus CD in the CD-ROM drive.
Step 2.
From the Start Menu, select Run.
Step 3.
Select Browse.
Step 4.
Select
D:\
for the CD-ROM drive.
Step 5.
Select
SETUP.EXE
and click OK.
Step 6.
Select MegaService Monitor.
The MegaService Monitor is now installed.