beautypg.com

4 logical drive menu, Table5.7 power console plus logical drive menu, Logical drive menu – Avago Technologies MegaRAID SATA 150-4 (523) User Manual

Page 119: Power console plus logical drive menu, Power console plus change configuration submenu

background image

Power Console Plus Interface Description

5-17

Version 2.0

Copyright © 2003–2006 by LSI Logic Corporation. All rights reserved.

5.4.4

Logical Drive Menu

Table 5.7

describes the Power Console Plus Logical Drive menu options.

Table 5.8

summarizes the Power Console Plus Change Configuration

submenu options.

Table 5.7

Power Console Plus Logical Drive Menu

Option

Description

Initialize

This option initializes the selected logical drives. The Power Console Plus utility
enables you to initialize a drive at any time.

Note: Warning: Initializing a drive deletes all its data.

Check Consistency

This option verifies the redundancy data in the selected logical drives that use
RAID levels 1, 5, 10, or 50. If a discrepancy is found, MegaRAID assumes that
the data is correct and corrects the parity value. If the failure is a read error on
a data drive, the bad data block is reassigned with the generated data.

Properties

This option displays the properties of the selected logical drive. A screen such
as the following appears. You can display each logical drive by selecting the
Previous or Next buttons.

Change Config

Through a submenu, this option enables you to change the cache policy, read
policy, write policy, RAID level, and virtual size of the logical drive. You can also
add capacity to the logical drive.

Table 5.8

Power Console Plus Change Configuration Submenu

Option

Description

Change Cache Policy

This option changes the cache memory policy. You can select Direct I/O or
Cached I/O.

Change Read Policy

This option changes the cache read policy. You can select Normal, Read
Ahead, or Adaptive Read Ahead.

Table 5.9

describes the read policy options.

Change Write Policy

This option changes the cache write policy. You can select write-back or
write-through.

Table 5.10

describes the write policy options.

RAID Level

This option changes the RAID level of the selected device.

Virtual Size

This option enables the Virtual Sizing feature. Virtual Sizing does not take
effect until a system reboot occurs.

Add Capacity

This option adds drive(s) to the specified logical drive.