beautypg.com

Tablea.5 messages for saf-te compliant boxes, Messages for saf-te compliant boxes – Avago Technologies MegaRAID SATA 150-4 (523) User Manual

Page 139

background image

MegaRAID Service Monitor Event Types

A-5

Version 2.0

Copyright © 2003–2006 by LSI Logic Corporation. All rights reserved.

Table A.5

describes the SAF-TE messages.

Table A.5

Messages for SAF-TE Compliant Boxes

Event Type

Severity Level

Log Messages

Informational

Adapter # Channel # Target # [Fans= #, Power Supplies= #,
Slots= # & Temperature Sensors= #] : SAF-TE Information

Temperature is over
threshold or back to
normal Fan is not
operational or its
status has changed
since last check

Warning

Temperature Sensor # is ?? Degree: Out of Range

Warning

Temperature Sensor # is Normal

Informational

Status of Fan # =0x##: Operational

Warning

Status of Fan # =0x##: Malfunctioning

Warning

Status of Fan # =0x##: Unknown Status

Warning

Status of Fan # =0x##: Status Not Reportable

Device slot ID
number changed

Warning

Device Slot # ID=#: The associated physical drive ID has changed.
Physical Drive # is Removed/Power Off. Physical Drive # is
Added/Power On.
These messages are not currently available.

Power supply is not
operational or its
status has changed
since last check

Informational

Status of Power Supply #=0x##: Operational and On

Warning

Status of Power Supply #=0x##: Operational and Off

Warning

Status of Power Supply #=0x##: Malfunctioning and
Commanded On

Warning

Status of Power Supply #=0x##: Malfunctioning and
Commanded Off

Warning

Status of Power Supply #=0x##: Not Present

Warning

Status of Power Supply #=0x##: Present

Warning

Status of Power Supply #=0x##: Unknown Status

Warning

Status of Power Supply #=0x##: Status Not Reportable