beautypg.com

Frequency modulation (fm), To select fm modulation, To select carrier waveform shape – RIGOL DG5000 Series User Manual

Page 81: To set carrier frequency, Frequency modulation (fm) -5

background image

Chapter 4 Common Modulation Output

RIGOL

User’s Guide for DG5000

4-5

Frequency Modulation (FM)


A FM (Frequency Modulation) modulated waveform consists of carrier waveform and
modulating waveform. The frequency of the carrier waveform varies with the
instantaneous voltage of the modulating waveform.

To Select FM Modulation

Press ModTypeFM to enable FM function.
 When Mod is enabled, Sweep or Burst will be disabled automatically (if

currently enabled).

 After FM is enabled, the instrument will generate FM waveform with the currently

specified carrier and modulating waveform.


To Select Carrier Waveform Shape

FM carrier waveform shape could be Sine, Square, Ramp or Arbitrary waveform. The
default is Sine.
 Press the front panel key Sine, Square, Ramp or (ArbSelect Wform) to

select a desired carrier waveform shape.

 Pulse (basic waveform), Noise and DC could not be used as carrier waveform.

To Set Carrier Frequency

After the carrier waveform shape is selected, press Freq/Period to highlight “Freq”,
and then use the numeric keyboard or knob to input desired frequency value. The
available carrier frequency varies with different carrier waveforms.
 Sine: 1 μHz to 350 MHz
 Square: 1 μHz to 120 MHz
 Ramp: 1 μHz to 5 MHz
 Arbitrary waveform: 1 μHz to 50 MHz