Play Mode
The generator will enable the “Play” mode once the number of points of the arbitrary
waveform to be output is greater than 16 Mpts and be able to output waveform with
up to 128 Mpts. In this mode, you can adjust the sample rate fs through setting the
frequency division coefficient N. The function relationship between fs and N is as
following:
When N≤2,
N
s
2
1G Sa/s
f =
When N>2,
8
2)
-
(N
1G Sa/s
f
s
×
=
The range of N is from 0 to 268435456 (2
28
).
As shown in the figure below, press Mode to select “Play”. As can be seen,
Freq/Period will change to Sample which denotes the frequency division coefficient