RIGOL DG5000 Series User Manual
Page 32
![background image](https://www.manualsdir.com/files/859118/content/doc032.png)
RIGOL
User’s Guide for DG5000
1-8
12. Page Up/Down
Open the previous or next page of the current function menu.
13. Menu Softkey
Press any softkey to activate the corresponding menu.
14. Modulation
Generate modulated waveforms. Provide versatile common modulations and user
defined IQ modulation.
Common Modulations: support internal and external modulations, generate
AM, FM, PM, ASK, FSK, PSK and PWM modulated signal.
User Defined IQ Modulation: support internal and external modulation,
generate IQ modulated signal.
15. Sweep
Generate the frequency sweeping signal of Sine, Square, Ramp and Arbitrary
Waveforms (except DC).
Support three sweep types: Linear, Log and Step.
Set Start Hold, End Hold and Return Time.
Provide the “Mark” function.
When the function is enabled, the backlight of the button turns on.
16. Burst
Generate burst waveforms of Sine, Square, Ramp, Pulse and Arbitrary waveform
(except DC).
Support three burst types: N Cycle, Infinite and Gated.
Noise can also be used to generate Gated burst.
When the function is enabled, the backlight of the button turns on.
In remote mode, press this button to switch to local mode.
17. Store/Recall
Store/recall the instrument state or user-defined arbitrary waveform data.
Support file management system to execute normal file operations.
Provide 1 GBytes built-in non-volatile memory (C Disk) and two external USB
storage devices (D Disk and E Disk). In addition, files stored in a USB storage
device can be copied to C Disk for long-term preservation.
When the function is enabled, the backlight of the button turns on.