beautypg.com

To output pulse waveform, To output pulse waveform -7 – RIGOL DG5000 Series User Manual

Page 55

background image

Chapter 2 Basic Waveform Output

RIGOL

User’s Guide for DG5000

2-7

To Output Pulse Waveform


To output a pulse waveform from CH1 with 20 kHz frequency, 2.5 Vpp amplitude, 500
mV

DC

offset, 10 μs pulse width (20% duty cycle), 50 ns leading and trailing edge time

and 8 μs delay. Refer to To Output Sine Waveform to configure the parameters
and output. This section will only talk about “Width/Duty”, “Leading”, “Trailing”,
“Delay” and “Restore”.













Pulse Width/Duty Cycle


Pulse Width is defined as the time from the 50% threshold of a leading edge
amplitude to the 50% threshold of the next trailing edge amplitude as shown in the
figure above. Duty Cycle is defined as the percentage that the pulse width takes up in
the pulse period.

Press Pulse Width/Duty to highlight “Pulse Width”, and then use the numeric
keyboard to input “10” and select the unit “μsec” in the pop-up menu.
 Pulse Width is limited by the Minimum Pulse Width” and the “Pulse Period”.

Minimum Pulse Width = 4 ns
Pulse Width ≥ Minimum Pulse Width
Pulse Width ≤ Pulse Period - Minimum Pulse Width × 2

 Pulse Width and Duty Cycle are correlative. Once a parameter is changed, the

Pulse Width

10%

Leading Edge Time

Trailing Edge Time

90%

50%