beautypg.com

Edit block, Edit block -13 – RIGOL DG5000 Series User Manual

Page 73

background image

Chapter 3 Arbitrary Waveform Output

RIGOL

User’s Guide for DG5000

3-13

Edit Block


The following example introduces how to create an arbitrary waveform which meets
the following conditions with the following conditions met by using “Edit Block”.

Parameter

Value

Cycle Period

12 μs

High VLimit

4 V

Low VLimit

-2 V

Interpolation

Linear

Start

2, 4 V

End

4, -2 V


Operating Procedures:

1.
Press Arb, use

to open the 2/2 menu page, and then press Create New

Cycle Period, use the numeric keyboard to input “12” and select the unit
“μsec” in the pop-up menu.

2. Press High VLimit, use the numeric keyboard to input “4” and select the unit “V”

in the pop-up menu.

3. Press Low VLimit, use the numeric keyboard to input “-2” and select the unit “V”

in the pop-up menu.

4. Press Init #Points, use the numeric keyboard to input4” and then press OK.

Note that a level line of -2 V appears.

5. Press Interp to select “Linear”.

6. Press Edit Block to enter the “Edit Block” interface.

1) Press X1 and use the numeric keyboard to input “2”. Then press Y1 and use

the numeric keyboard to input “4” and select the unit “V” in the pop-up menu.
Use the same method to set X2 and Y2.

2) Press Excute to apply the setting defined in step 1). The waveform editor will